3 Revolutionary Way Court

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- Electrical · Several outdoor outlets have no power, laundry room outlet unsafe · 2026
- Foundation · Basement foundation cracks letting moisture into the home · 2026
- Sewer · Small dent in sewer pipe needs monitoring with re-inspection in two years · 2026
- Roof · Aging roof shows signs of hail damage, may need replacement · 2026
- Plumbing · Water heater from 2007 is aging and pool pump base is cracked · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 3 Revolutionary Way Court, O'Fallon, MO 63366, dated in July 2026.
Home Inspection Document
On July 7, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 3 Revolutionary Way Court, O'Fallon, MO 63366.
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Sewer
- Home InspectionWhole-home inspection of single-family property found no structural issues overall, but identified multiple deficiencies across roofing, foundation, electrical, pest, and other systems requiring attention.
- SewerNo blockages or damages observed in sewer lines; a small indentation is present in the PVC roughly 10' in from the city main tap, with re-scoping recommended in two years to monitor for growth.
- FoundationMultiple common cracks present in the basement foundation wall; three cracks are allowing moisture intrusion and need epoxy injections, with smaller cracks to be filled with urethane; sloped rear patio brickwork may be promoting moisture intrusion on the rear-facing basement wall.
- RoofArchitectural shingle roof estimated 20-25 years old (possibly original) is performing but shows signs of age and hail damage; drone inspection conducted.
- ElectricalThree exterior GFCI outlets have no power (possibly downstream from a hidden GFCI); laundry room lacks GFCI-protected outlet; 200-amp Murray service panel in basement appears functional.
- HVACCarrier central split system (77,000 BTU furnace mfgd 2016, 3-ton condenser mfgd 2015) performs properly but requires annual cleaning and servicing; two bathroom exhaust fans vent into the attic and need extension to exterior.
- PlumbingGeneral Electric 50-gallon natural gas water heater manufactured in 2007 is functioning properly; pool pump base has a crack and likely needs replacement as the casing is nearly impossible to repair.
- PestOlder termite damage is present on a front yard tree stump; inspector recommends removing the stump or treating with a borate-based solution such as Bora-Care.
- PestWDI inspection of SFR/Attached Garage at 3 Revolutionary Way Court, O'Fallon, MO found older termite damage on a front yard tree stump; treatment recommended — spray the area with a borate-based solution.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.