- HVAC · AC system recharged with R-22 refrigerant · Aug 2026
- HVAC · Diagnostic readings showed low cooling capacity at time of service · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 301 Oriole Drive, St. Charles, MO 63301. The amount summary includes $1,200 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Refrigerant Recharge — R-22 refrigerant added to HVAC system
- HVAC
Built from Housecall Pro data
- $1,200HVACCharged the HVAC system with R-22 refrigerant (6.5 lb billed) and a trip fee was applied.
- HVACPhotograph shows Fieldpiece app HVAC air-side measurements: Return dry bulb 76.2°F / wet bulb 67.2°F / RH 62.7% / dew point 62.5°F / enthalpy 31.7 Btu/lbm; Supply dry bulb 73.1°F / wet bulb 66.1°F / RH 69.1% / dew point 62.3°F / enthalpy 30.8 Btu/lbm; Delta T 3.1°F; Refrigerant side suction pressure 74.4 psig and liquid pressure 251.1 psig.
- HVACFieldpiece app measurements show R-22 refrigerant system with suction pressure 74.3 psig, liquid pressure 245.0 psig, actual superheat 15.3°F, and actual subcooling 12.7°F; air side diagnostics show no dry bulb readings.
- HVACFieldpiece diagnostic app shows R-22 system with suction pressure 74.3 psig, liquid pressure 251.0 psig, actual superheat 16.8°F, actual subcooling 14.8°F; air side diagnostics indicate supply air dry bulb (73.1°F) is above target evaporator exit dry bulb (60.3°F), which usually indicates low capacity.
- HVACPhotograph shows a Yellow Jacket digital gauge displaying a reading of -9.37, resting on bare soil outdoors alongside a blue tool or hose.
- HVACgas supply pipes are visible at the base of the unit, and debris/dust accumulation is visible around the flue collar at the top of the furnace