Hi, I'm 3023 Wyoming Street. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
3023 Wyoming Street
Across 1 record on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · HVAC service visit with trip fee and 1.5 hours labor · Aug 2026
- HVAC · Outdoor AC unit data plate shows manufacture date March 2023 · 2026
- HVAC · Air handler and condensate drain pan area inspected at service visit · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 3023 Wyoming Street, St. Louis, MO 63118. The amount summary includes $284 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Trip fee and 1.5 hrs HVAC labor
- HVAC
Built from Housecall Pro data
- $284HVACTrip fee and 1.5 hours of residential labor (non-member) performed at the service address.
- HVACPhotograph shows the manufacturer data plate on an outdoor air conditioner condenser unit, model N4A4S30AKANAABAB, serial E231004995, factory charged with 6.00 lbs R410A, manufactured March 2023.
- HVACFieldpiece app refrigerant side measurements for R-410A system show suction pressure 137.7 psig, suction temperature 61.8°F, actual superheat 13.8°F, liquid pressure 369.7 psig, liquid temperature 100.5°F, actual subcooling 10.1°F, and Delta T 16.2°F.
- HVACFieldpiece app measurements show air side Delta T of 19.3°F (return dry bulb 87.8°F, supply dry bulb 68.5°F), return RH 59.7%, supply RH 88.9%, and refrigerant side suction 148.7 psig / liquid 370.1 psig.
- HVACFieldpiece app air-side measurements show return dry bulb 77.5°F, supply dry bulb 61.4°F, Delta T 16.1°F, return RH 66.6%, supply RH 91.0%, return enthalpy 33.4 Btu/lbm, supply enthalpy 26.3 Btu/lbm; Btu capacity reading is blank.
- HVACFieldpiece refrigerant diagnostic shows R-410A system with suction pressure 139.2 psig, liquid pressure 368.3 psig, actual superheat 13.7°F, actual subcooling 9.8°F, and air side diagnostics indicating adequate airflow across the evaporator coil.
- HVACPhotograph shows an HVAC air handler unit with insulated copper refrigerant lines routed along the wall, white PVC condensate drain piping at the base, and a sheet metal supply plenum at the bottom; the top surface of the plenum shows visible staining or discoloration.
- HVACa yellow-handled tool is visible near the unit
- HVACPhotograph shows an HVAC air handler unit mounted above a galvanized sheet metal plenum, with copper refrigerant lines connected and a white PVC condensate drain line running horizontally from the unit.
- HVACFieldpiece diagnostic app shows R-410A system with suction pressure 141.4 psig, liquid pressure 363.0 psig, actual superheat 13.7°F, actual subcooling 10.0°F, and adequate airflow across the evaporator coil indicated by supply air dry bulb (62.0°F) near target (61.5°F).
- HVACPhotograph shows a Fluke 323 True RMS Clamp Meter displaying 0.6 A AC, being held near electrical wiring and what appears to be HVAC equipment in the background.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,