HVAC Service Call — Trip fee and 1.5 hrs HVAC labor
- HVAC
On August 11, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 3023 Wyoming Street, St. Louis, MO 63118.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$284
Trip fee and 1.5 hours of residential labor (non-member) performed at the service address.
- HVACWork status not resolved
Photograph shows the manufacturer data plate on an outdoor air conditioner condenser unit, model N4A4S30AKANAABAB, serial E231004995, factory charged with 6.00 lbs R410A, manufactured March 2023.
- HVACWork status not resolved
Fieldpiece app refrigerant side measurements for R-410A system show suction pressure 137.7 psig, suction temperature 61.8°F, actual superheat 13.8°F, liquid pressure 369.7 psig, liquid temperature 100.5°F, actual subcooling 10.1°F, and Delta T 16.2°F.
- HVACWork status not resolved
Fieldpiece app measurements show air side Delta T of 19.3°F (return dry bulb 87.8°F, supply dry bulb 68.5°F), return RH 59.7%, supply RH 88.9%, and refrigerant side suction 148.7 psig / liquid 370.1 psig.
- HVACWork status not resolved
Fieldpiece app air-side measurements show return dry bulb 77.5°F, supply dry bulb 61.4°F, Delta T 16.1°F, return RH 66.6%, supply RH 91.0%, return enthalpy 33.4 Btu/lbm, supply enthalpy 26.3 Btu/lbm; Btu capacity reading is blank.
- HVACWork status not resolved
Fieldpiece refrigerant diagnostic shows R-410A system with suction pressure 139.2 psig, liquid pressure 368.3 psig, actual superheat 13.7°F, actual subcooling 9.8°F, and air side diagnostics indicating adequate airflow across the evaporator coil.
- HVACWork status not resolved
Photograph shows an HVAC air handler unit with insulated copper refrigerant lines routed along the wall, white PVC condensate drain piping at the base, and a sheet metal supply plenum at the bottom; the top surface of the plenum shows visible staining or discoloration.
- HVACWork status not resolved
a yellow-handled tool is visible near the unit
- HVACWork status not resolved
Photograph shows an HVAC air handler unit mounted above a galvanized sheet metal plenum, with copper refrigerant lines connected and a white PVC condensate drain line running horizontally from the unit.
- HVACWork status not resolved
Fieldpiece diagnostic app shows R-410A system with suction pressure 141.4 psig, liquid pressure 363.0 psig, actual superheat 13.7°F, actual subcooling 10.0°F, and adequate airflow across the evaporator coil indicated by supply air dry bulb (62.0°F) near target (61.5°F).
- HVACWork status not resolved
Photograph shows a Fluke 323 True RMS Clamp Meter displaying 0.6 A AC, being held near electrical wiring and what appears to be HVAC equipment in the background.