HVAC Maintenance Invoice — Air conditioning maintenance visit
- HVAC
On April 8, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 3092 Woodbridge Creek Drive, St. Louis, MO 63129.
- Record date
Available findings
- HVACCompleted work
Air conditioning maintenance performed under the Residential Maintenance Plan.
- HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge set connected to an R410A refrigerant system, displaying low-side pressure of 103.0 psig with 3.5°F superheat and high-side pressure of 236.8 psig with 9.5°F subcooling.
- HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge connected to an R410A refrigerant system, displaying evaporator-side readings of 32.7°F and 102.7 psig and condenser-side readings of 78.5°F and 231.3 psig.
- HVACWork status not resolved
refrigerant manifold gauge hoses are also visible, indicating active HVAC service
- HVACWork status not resolved
Photograph shows a heavily soiled HVAC air filter with a metal mesh/electrostatic-style frame, uniformly darkened with accumulated dust and debris across the entire filter surface, indicating it is well past due for replacement or cleaning.
- HVACWork status not resolved
wiring compartment shows heavy dust and debris accumulation
- HVACWork status not resolved
heavy dust and debris accumulation is visible on the wiring and components
- HVACWork status not resolved
the capacitor and surrounding wiring show heavy dust and cobweb accumulation