- HVAC · Air conditioning maintenance performed under a Residential Maintenance Plan · Apr 2026
- HVAC · HVAC service visit recorded with no itemized work lines · Oct 2026
- HVAC · Furnace data plate shows a 2014 manufacture date · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 3092 Woodbridge Creek Drive, St. Louis, MO 63129, dated from April 2026 through October 2026.
HVAC Maintenance Invoice — Air conditioning maintenance visit
- HVAC
Built from Housecall Pro data
- HVACAir conditioning maintenance performed under the Residential Maintenance Plan.
- HVACPhotograph shows a Testo 557 digital manifold gauge set connected to an R410A refrigerant system, displaying low-side pressure of 103.0 psig with 3.5°F superheat and high-side pressure of 236.8 psig with 9.5°F subcooling.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an R410A refrigerant system, displaying evaporator-side readings of 32.7°F and 102.7 psig and condenser-side readings of 78.5°F and 231.3 psig.
- HVACrefrigerant manifold gauge hoses are also visible, indicating active HVAC service
- HVACPhotograph shows a heavily soiled HVAC air filter with a metal mesh/electrostatic-style frame, uniformly darkened with accumulated dust and debris across the entire filter surface, indicating it is well past due for replacement or cleaning.
- HVACwiring compartment shows heavy dust and debris accumulation
- HVACheavy dust and debris accumulation is visible on the wiring and components
- HVACthe capacitor and surrounding wiring show heavy dust and cobweb accumulation
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge HVAC service visit
- HVAC
Built from Housecall Pro data
- HVACHVAC service visit on the service date with no service lines itemized.
- HVACPhotograph shows a Rheem forced-air furnace data plate: Model R801SA100521MSA, Serial W361432810, manufactured 09/2014, 100,000 BTU/hr max input, factory equipped for natural gas.
- HVACPhotograph shows a Foxwell inspection camera screen displaying the interior of a pipe at 4x zoom, with visible reddish-brown discoloration, rough/corroded pipe walls, debris buildup, and a vertical line or seam on the pipe surface.