- HVAC · HVAC system inspected and refrigerant pressures measured · 2026
- HVAC · Condenser coil tubes show surface discoloration and age-related wear · 2026
- HVAC · Air handler filters were visibly in place at inspection · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 3212 Laclede Station Road, Maplewood, MO 63143, dated in September 2026.
HVAC Service Invoice — No-charge HVAC service visit
- HVAC
Built from Housecall Pro data
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge HVAC service visit
- HVAC
Built from Housecall Pro data
- HVACPhotograph shows large looping heat exchanger tubes or coils with visible rust, orange-brown corrosion at bends and seams, surface staining on the white coating, and a corroded metal pipe visible in the background interior of the unit.
- HVACPhotograph shows a Fluke 323 True RMS Clamp Meter with the rotary dial set to OFF and the LCD display showing approximately '5', being held near metal equipment.
- HVACa handwritten date reading '10/22/26' is visible on the filter frame
- HVACFieldpiece app refrigerant side measurements for R-410A system: suction pressure 126.6 psig, liquid pressure 302.4 psig, suction temp 48.4°F, liquid temp 79.4°F, vapor saturation 43.5°F, liquid saturation 96.4°F, actual superheat 4.9°F, actual subcooling 17.0°F, discharge pressure 302.4 psig.
- HVACPhotograph shows furnace heat exchanger tubes with heavy surface rust, orange-brown corrosion staining, and visible cracking or splitting at the tube seams, indicating significant deterioration of the heat exchanger.
- HVACPhotograph shows Fieldpiece app screen displaying live R-410A refrigerant measurements: suction pressure 130.1 psig, suction temperature 47.0°F, actual superheat 2.1°F; liquid pressure 320.0 psig, liquid temperature 84.5°F, actual subcooling 15.8°F, discharge pressure 320.0 psig.