Hi, I'm 3243 Delor Street. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
← MAPSOURCE-BACKED RECORDS
3243 Delor Street
St. Louis, MO 6311138.5701°N, 90.2436°W
1Event
Contributed by:1 contributor

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · Unit 1 furnace is past expected life; central AC inoperable · 2026
- Electrical · Both units have older 100-amp electrical service panels · 2026
- Plumbing · Active bathroom sink leak causing ongoing water damage in Unit 2 · 2026
- Mold · Mildew found inside bathroom sink cabinet in Unit 2 · 2026
- Roof · Soffit damage on front corner of building needs repair · 2026
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
1 documented event
Contributed by: 1 contributor
First documented event: Aug 2026
Latest documented event: Aug 2026
First added to Fresh House: Aug 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 1 documented record for 3243 Delor Street, St. Louis, MO 63111, dated in August 2026.
Home Inspection
Home Inspection Document
Inspected Aug 7, 2026Uploaded Aug 8, 20262 files
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 5 other topics at 3243 Delor Street, St. Louis, MO 63111.
Scope
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Mold,
- Plumbing,
- Roof,
- Sewer
Contributor
worked on or inspected it- Home InspectionWhole-home inspection of two-family building at 3243 Delor St found the property in generally good condition with no structural issues; six deficiencies identified across roofing, HVAC, plumbing, and mold.
- ElectricalBoth Unit #1 and Unit #2 have Eaton 100-amp service panels with breakers located in the basement; smoke detectors present in both units.
- FoundationBasement foundation of stone construction with wood-framed floors and masonry wall structure; no structural issues detected.
- HVACUnit #1 has a 1998 York gas furnace (92,000 BTU) that has hit the end of expected life; Unit #2 has a 2019 Comfortmaker gas furnace (66,000 BTU), but the central AC is inoperable per the occupant; 3 AC condensers on roof (2 older, 1 newer), and the occupant relies on window units; missing dryer exhaust vents also noted in Unit #2 laundry.
- MoldMildew has formed inside the bathroom sink cabinet in Unit #2 as a result of the ongoing plumbing leak under the sink.
- PlumbingUnit #2 bathroom sink has an active plumbing leak that has persisted for months despite a report to property management; both basement laundry hookups drain into the laundry sink (improperly plumbed) and the laundry sink faucet is inoperable; both units have 2018 Rheem 40-gallon electric water heaters.
- RoofTPO roofing estimated 1-2 years old and in great shape; deficiency noted; soffit damage on the front corner of the building requires repair.
- SewerNo damages or obstructions were observed to the sewer lateral lines.
- SewerSewer lateral inspection found lines open and flowing with no visible damage; lines are PVC all the way to the city's main connection.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedSewer
✓ documentedFoundation
✓ documentedMold
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
undocumentedRadon
undocumentedAppraisals
undocumentedWindows
undocumented