- HVAC · Dual capacitor replaced on the outdoor AC unit · Sep 2026
- HVAC · HVAC service trip performed at the property · Sep 2026
- HVAC · Separate HVAC service visit recorded with no itemized work · Feb 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 33 Oak Hill Drive, Ellisville, MO 63021, dated in February 2026. The amount summary includes $434 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Invoice — No-charge HVAC service visit
- HVAC
Built from Housecall Pro data
- HVACHVAC service visit on February 23, 2026 at 33 Oak Hill Drive with no service lines itemized and no charge.
- HVACPhotograph shows a State Water Heaters ProLine Commercial Grade tank water heater with copper supply and return piping, a blue-handled gate valve on the inlet/outlet connection, and a large white PVC drain/vent pipe overhead labeled 'NOT FOR PRESSURE'; blue painter's tape is visible on the tank exterior.
- HVACPhotograph shows a gas furnace with attached whole-house humidifier, vertical sheet metal supply plenum and flue pipe, PVC condensate drain lines, and flexible metallic conduit in an unfinished utility space with R-13 batt insulation on the adjacent wall.
- HVACPhotograph shows a large blower wheel assembly with visible electrical wiring (blue and yellow conductors) and associated HVAC cabinet components, including what appear to be flue or refrigerant lines.
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Capacitor Replacement — Dual capacitor replaced
- HVAC
Built from Housecall Pro data
- $434HVACReplaced dual capacitor and performed a service trip.
- HVACPhotograph shows a dual-run capacitor (45/7.5μF, 440VAC, model HC98KA047) mounted inside an outdoor condenser cabinet, with heavy cobwebs and debris accumulation throughout the interior compartment.
- HVACPhotograph shows the data plate of a central cooling air conditioner (Model 116BNA048-B, Serial 3214E14001) manufactured August 2014, factory charged with R410A refrigerant, rated 208-230V/1PH/60Hz, Energy Star certified.
- HVACPhotograph shows an outdoor HVAC condenser unit with access panel open and multiple wires exposed
- HVACPhotograph shows a Testo 557 digital manifold gauge displaying refrigerant system readings: superheat (SH) 19.5°F, subcooling (SC) 10.0°F, low-side pressure 138.9 psi, and high-side pressure 327.9 psi, with refrigerant type indicated as R410A.
- HVACPhotograph shows a 20x25x1 HVAC air filter leaning against a furnace unit in a basement utility room; the filter media appears visibly dirty/dust-laden, with pink fiberglass batt insulation and a white PVC condensate pipe visible in the background.
- HVACPhotograph shows an exterior electrical junction box mounted to the underside of a concrete soffit with two conduits attached; the larger conduit exhibits severe deterioration with cracked, split, and disintegrating outer sheathing, and the mounting hardware shows visible rust and corrosion.
- HVACPhotograph shows an outdoor AC condenser unit with its electrical compartment open
- HVACPhotograph shows a Testo 557 digital manifold gauge displaying R410A refrigerant readings: evaporator side 216.0 psi / 74.4°F and condenser side 252.4 psi / 84.1°F.
- HVACheavy accumulation of dust, cobwebs, and debris is visible throughout the compartment
- HVACPhotograph shows the interior electrical compartment of an outdoor HVAC condenser unit with an existing cylindrical capacitor mounted inside and a new 45/7.5μF ±6% CBB65B 440VAC dual run capacitor being held up, alongside a contactor/relay board and multiple wiring connections, with heavy dust, debris, and cobwebs throughout the compartment.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.