Complete public upload archive

Property records for 33 Oak Hill Drive, Ellisville, MO 63021

All 2 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 2.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Service Invoice — No-charge HVAC service visit

  • HVAC

On February 23, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 33 Oak Hill Drive, Ellisville, MO 63021.

Record date

Available findings

  • HVACCompleted work

    HVAC service visit on February 23, 2026 at 33 Oak Hill Drive with no service lines itemized and no charge.

  • HVACWork status not resolved

    Photograph shows a State Water Heaters ProLine Commercial Grade tank water heater with copper supply and return piping, a blue-handled gate valve on the inlet/outlet connection, and a large white PVC drain/vent pipe overhead labeled 'NOT FOR PRESSURE'; blue painter's tape is visible on the tank exterior.

  • HVACWork status not resolved

    Photograph shows a gas furnace with attached whole-house humidifier, vertical sheet metal supply plenum and flue pipe, PVC condensate drain lines, and flexible metallic conduit in an unfinished utility space with R-13 batt insulation on the adjacent wall.

  • HVACWork status not resolved

    Photograph shows a large blower wheel assembly with visible electrical wiring (blue and yellow conductors) and associated HVAC cabinet components, including what appear to be flue or refrigerant lines.

Record 2Public property record

HVAC Capacitor Replacement — Dual capacitor replaced

  • HVAC

On September 4, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 33 Oak Hill Drive, Ellisville, MO 63021.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$434

    Replaced dual capacitor and performed a service trip.

  • HVACWork status not resolved

    Photograph shows a dual-run capacitor (45/7.5μF, 440VAC, model HC98KA047) mounted inside an outdoor condenser cabinet, with heavy cobwebs and debris accumulation throughout the interior compartment.

  • HVACWork status not resolved

    Photograph shows the data plate of a central cooling air conditioner (Model 116BNA048-B, Serial 3214E14001) manufactured August 2014, factory charged with R410A refrigerant, rated 208-230V/1PH/60Hz, Energy Star certified.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit with access panel open and multiple wires exposed

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge displaying refrigerant system readings: superheat (SH) 19.5°F, subcooling (SC) 10.0°F, low-side pressure 138.9 psi, and high-side pressure 327.9 psi, with refrigerant type indicated as R410A.

  • HVACWork status not resolved

    Photograph shows a 20x25x1 HVAC air filter leaning against a furnace unit in a basement utility room; the filter media appears visibly dirty/dust-laden, with pink fiberglass batt insulation and a white PVC condensate pipe visible in the background.

  • HVACWork status not resolved

    Photograph shows an exterior electrical junction box mounted to the underside of a concrete soffit with two conduits attached; the larger conduit exhibits severe deterioration with cracked, split, and disintegrating outer sheathing, and the mounting hardware shows visible rust and corrosion.

  • HVACWork status not resolved

    Photograph shows an outdoor AC condenser unit with its electrical compartment open

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge displaying R410A refrigerant readings: evaporator side 216.0 psi / 74.4°F and condenser side 252.4 psi / 84.1°F.

  • HVACWork status not resolved
  • HVACWork status not resolved

    heavy accumulation of dust, cobwebs, and debris is visible throughout the compartment

  • HVACWork status not resolved

    Photograph shows the interior electrical compartment of an outdoor HVAC condenser unit with an existing cylindrical capacitor mounted inside and a new 45/7.5μF ±6% CBB65B 440VAC dual run capacitor being held up, alongside a contactor/relay board and multiple wiring connections, with heavy dust, debris, and cobwebs throughout the compartment.

View 33 Oak Hill Drive, Ellisville, MO 63021 on Fresh House