Hi, I'm 34 Country Crossing Estates Drive. I only speak from this property's source-backed records — 2 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
34 Country Crossing Estates Drive
Across 2 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 2 documented records
Fresh House Property Summary
Highlights selected from 2 documented records for this property.
- HVAC · AC and furnace replacement estimated but not confirmed done · Aug 2026
- HVAC · Existing outdoor AC unit uses R-22 refrigerant · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 34 Country Crossing Estates Drive, St. Peters, MO 63376, dated in August 2026. The amount summary includes $11,730.50 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Estimate — 4-ton AC + 120K gas furnace
- HVAC
Option: 14 SEER 4-ton AC & Gas Furnace (120K) $11,730.50 (expired)
Built from Housecall Pro data
- $11,731HVACEstimate for a 14 SEER 4-ton American Standard AC and 120K BTU gas furnace with evaporator coil, disconnect, Wi-Fi thermostat, flue pipe, pads, materials and labor.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge HVAC service visit
- HVAC
Built from Housecall Pro data
- HVACPhotograph shows a Fluke 323 True RMS Clamp Meter reading 17.8 AAC, being used to measure current draw at what appears to be an outdoor HVAC condenser unit with visible wiring and refrigerant lines in the background.
- HVACFieldpiece app measurements show air-side Delta T of 13.9°F (return dry bulb 71.3°F, supply dry bulb 57.4°F), return RH 63.7%, supply RH 84.6%, and refrigerant-side suction pressure 60.1 psig / liquid pressure 250.6 psig.
- HVACPhotograph shows a mobile HVAC diagnostic app screen displaying air-side measurements: return dry bulb 71.4°F, supply dry bulb 57.4°F, Delta T 14.0°F; return RH 63.7%, supply RH 84.6%; Btu capacity field is blank. Refrigerant side section is partially visible but cut off.
- HVACFieldpiece app diagnostic shows R-22 system with suction pressure 59.5 psig, actual superheat 32.9°F (elevated), liquid pressure 251.9 psig, actual subcooling 8.4°F, and air-side dry bulb 57.5°F near target 54.8°F indicating adequate evaporator airflow.
- HVACPhotograph shows an electrical contactor or relay block (terminals labeled 21 and 23) with multiple wires heavily coated in dust, lint, and cobwebs, indicating significant accumulation and lack of maintenance.
- HVACPhotograph shows the manufacturer data plate on an outdoor central cooling air conditioner: Model 38CKC048300, Serial 1600E23580, factory charged with R-22 (6.63 lbs), 208-230V/1PH/60Hz power supply, 24.4A RLA compressor, 1/4 HP fan motor, min circuit amps 31.9, max fuse 50A.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.