- HVAC · Blower motor replaced during HVAC diagnostic service visit · Jan 2026
- HVAC · AC evaporator coil chemically cleaned and disinfected · Jan 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 3407 Park Avenue, St. Louis, MO 63104. The amount summary includes $939 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Blower Motor Replacement — Blower motor replaced
- HVAC
Built from Housecall Pro data
- $939HVACPerformed diagnostic service, replaced the blower motor, and cleaned the air conditioning evaporator coil with chemical cleaning and disinfectant.
- HVACPhotograph shows an HVAC evaporator coil assembly with heavy accumulation of black debris and grime on coil fins and surrounding sheet metal panels, significant rust/corrosion on the cabinet exterior and copper refrigerant lines, and debris buildup in the drain pan area.
- HVACPhotograph shows the interior of a gas furnace with active blue flames at two burner ports and heavy rust/corrosion on the burner manifold and surrounding metal components
- HVACPhotograph shows a Fieldpiece combustion analyzer attached to a gas furnace cabinet with a probe inserted into the flue pipe, displaying readings of 262.4°F stack temperature, 8.4% O2, 23 CO ppm, 38 CO2 ppm, and efficiency values; a Milwaukee drill is visible on the furnace base.
- HVACPhotograph shows a galvanized metal flue pipe with visible rust, corrosion, and cracking at the collar joint where two pipe sections connect, with rust staining streaking down the pipe below the joint.
- HVACPhotograph shows a borescope/inspection camera screen displaying the interior of a pipe with visible cracks or fractures in the pipe wall, recorded at 113°F on 01-27-2026.
- HVACPhotograph shows an A-frame evaporator coil (Model EDD2X36BA2, manufactured March 2007) with heavy rust and corrosion on the surrounding sheet metal housing and significant dirt/debris accumulation on the coil fins and drain pan area.
- HVACPhotograph shows a sewer/pipe inspection camera screen displaying the interior of a pipe with a visible crack or fracture line and a dark gap or joint defect; camera timestamp reads 01-27-2026 at 08:36, ambient temperature 113°F.