- HVAC · AC capacitor replaced after shorted wires and bad capacitor found · May 2022
- HVAC · Wiring repaired and refrigerant charge topped off · May 2022
- HVAC · Indoor unit filters replaced and contactor supplied · May 2022
RECORD SUMMARY
1 permit record on this page come from the City of St. Louis permit database. Community records come from 1 contributor.
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 3517 PARK AV, St. Louis, MO 63104, dated from February 2020 through May 2022. The amount summary includes $741.63 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call Repair — Bad capacitor, shorted wires; R-22 added
- HVAC
Built from Housecall Pro data
- $742HVACFound shorted wires and a bad capacitor; replaced the capacitor, fixed wires, replaced filters on indoor units, checked system charge and added 1.7 pounds of R-22, and supplied a contactor.
- HVACPhotograph shows an outdoor HVAC condenser unit with access panel open; a new Global P/C dual-run capacitor (35+5 μF) is installed and wired, while the old capacitor with burned/melted terminals lies discarded on the ground; refrigerant manifold gauge hoses are connected to service ports.
- HVACPhotograph shows a cylindrical run capacitor removed from an outdoor HVAC condenser unit with its top blown out, terminals blackened, and a wire visibly scorched and displaced, indicating catastrophic capacitor failure.
- HVACPhotograph shows a Fieldpiece SMAN Refrigerant Manifold + Micron Gauge placed on top of an outdoor condenser unit, displaying R22 refrigerant readings: low-side 67.2 Psig (SH 57.9, VSAT 39.0), high-side 222.1 Psig (SC 14.7, LSAT 108.6), SLT 96.9, LLT 93.9.
- HVACPhotograph shows a catastrophically failed HVAC capacitor with its top blown open, melted, and heavily charred, indicating a burn/explosion event inside the unit's electrical compartment.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
AB Permit AB-2020-554759
On February 5, 2020, City of St. Louis documented a property record at 3517 PARK AV, St. Louis, MO 63104.
Declared on the permit, not confirmed spending or proof of completed work.
Obtained from a public records source; may contain reporting delays or errors.
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.