HVAC Service Call Repair — Bad capacitor, shorted wires; R-22 added
- HVAC
On May 13, 2022, ASSURED HEATING AND COOLING documented HVAC at 3517 PARK AV, St. Louis, MO 63104.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$742
Found shorted wires and a bad capacitor; replaced the capacitor, fixed wires, replaced filters on indoor units, checked system charge and added 1.7 pounds of R-22, and supplied a contactor.
- HVACWork status not resolved
Photograph shows an outdoor HVAC condenser unit with access panel open; a new Global P/C dual-run capacitor (35+5 μF) is installed and wired, while the old capacitor with burned/melted terminals lies discarded on the ground; refrigerant manifold gauge hoses are connected to service ports.
- HVACWork status not resolved
Photograph shows a cylindrical run capacitor removed from an outdoor HVAC condenser unit with its top blown out, terminals blackened, and a wire visibly scorched and displaced, indicating catastrophic capacitor failure.
- HVACWork status not resolved
Photograph shows a Fieldpiece SMAN Refrigerant Manifold + Micron Gauge placed on top of an outdoor condenser unit, displaying R22 refrigerant readings: low-side 67.2 Psig (SH 57.9, VSAT 39.0), high-side 222.1 Psig (SC 14.7, LSAT 108.6), SLT 96.9, LLT 93.9.
- HVACWork status not resolved
Photograph shows a catastrophically failed HVAC capacitor with its top blown open, melted, and heavily charred, indicating a burn/explosion event inside the unit's electrical compartment.