3511 Pennsylvania Avenue
St. Louis, MO 6311838.5921°N, 90.2342°W
1Event
Contributed by:1 contributor

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- Electrical · Smoke detectors in Unit 1 are inoperable and need fixing · 2026
- HVAC · Both units have 2024 air conditioning condensers and 2009 furnaces · 2026
- Foundation · Basement foundation is sound but brick exterior has minor damage needing repair · 2026
- Plumbing · Unit 1 water heater is fully wrapped and condition is unknown · 2026
- Roof · Roll roofing is about 5 years old and performing properly · 2026
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
1 documented event
Contributed by: 1 contributor
First added to Fresh House: Sep 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 1 documented record for 3511 Pennsylvania Avenue, St. Louis, MO 63118.
DOCUMENTED
Home Inspection
Uploaded Sep 2, 20262 files
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 5 other topics at 3511 Pennsylvania Avenue, St. Louis, MO 63118.
Scope
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Windows
- Home InspectionWhole-home inspection of a 2-family property found no structural deficiencies; 7 deficiencies noted across exterior, electrical, plumbing, and interior systems, with inoperable smoke detectors as the primary life-safety concern.
- ElectricalSmoke detectors in Unit #1 are inoperable; functioning smoke detectors must be installed throughout both units; both units have 200-amp Square D breaker panels located in the basement.
- FoundationBasement foundation in acceptable condition with no moisture intrusion observed; brick masonry exterior has minor damage at top corner requiring repair and tuck-pointing; rear balcony and patio are structurally sound but need painting and have loose bannisters to secure.
- HVACBoth units have 2009 Goodman electric forced-air furnaces (appearing functional) and 2024 Goodman 2.5-ton split-system AC condensers; Unit #1 uses flexible ducting, Unit #2 uses metal ducting.
- PlumbingPVC supply and waste pipes in both units; Unit #1 water heater is completely wrapped and condition is unknown; seller information recommended; Unit #2 has a 40-gallon electric water heater appearing functional; loose kitchen faucet in Unit #2 requires securing.
- RoofRoll roofing estimated 5 years old and performing properly; metal gutters present; inspected via drone.
- WindowsWood, vinyl, and aluminum windows present; caulking around windows and doors recommended as needed.
- Pestno action or treatment recommended
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedWindows
✓ documentedSewer
undocumentedMold
undocumentedRadon
undocumentedAppraisals
undocumented