- HVAC · Furnace and AC system inspected · Aug 2026
- HVAC · Multiple HVAC repairs estimated but not confirmed complete · Aug 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 3518 Saint Blase Lane, St. Ann, MO 63074, dated in August 2026. The amount summary includes $290 in completed work across HVAC, $1,745 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Inspection Invoice — Furnace and AC system inspections
- HVAC
Built from Housecall Pro data
- $290HVACPerformed a furnace inspection and an AC system inspection.
- HVACPhotograph shows a yellow corrugated flexible gas connector running from a fitting on a large appliance (furnace or boiler) to a black vertical gas pipe riser in a basement; the connector hangs in a loop and is secured to the riser with a clamp fitting.
- HVACPhotograph shows furnace heat exchanger cells with visible rust, corrosion, and apparent cracking or deterioration on the metal clamshell surfaces, along with heavy dust accumulation throughout the furnace interior.
- HVACPhotograph shows the interior panel of a gas furnace with a bilingual manufacturer's installation label detailing minimum clearance requirements to combustible materials for upflow, counterflow, and horizontal positions, chassis width part numbers (SBT 14, SBT 17, SBT 21), and compatibility with natural gas and propane.
- HVACPhotograph shows the interior wiring compartment of an HVAC air handler or furnace with heavy dust and debris accumulation, a central contactor/relay component, a large disorganized bundle of multi-colored control wires, and a partially visible circuit board.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an R22 refrigerant system, displaying evaporator-side pressure of 57.7 psi at 32.0°F and condenser-side pressure of 179.4 psi at 94.0°F.
- HVACthe vent louvers show visible dust and debris accumulation
- HVACPhotograph shows an outdoor AC condenser unit with the coil fins heavily packed with dirt, dust, lint, and organic debris visible through the louver grille, severely restricting airflow through the condenser.
- HVACPhotograph shows an unfinished basement ceiling with a large black sheet-metal plenum connected to an air handler unit (partially labeled 'AF-100'), multiple round metal duct branches joined with Nashua 324A foil tape, and one large round duct with an open/uncapped end facing downward; exposed wood floor joists are visible above.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Repair Estimate — Immediate HVAC repairs incl. dual capacitor
- HVAC
Option: Recommend and necessary immediate repairs $1,745 (expired)
Built from Housecall Pro data
- $1,745HVACEstimate for evaporator cleaning, furnace door switch, blower motor cleaning, dual capacitor replacement, flexi gas line replacement, and a 30-amp fused electric disconnect.