HVAC Inspection Invoice — Furnace and AC system inspections
- HVAC
On August 24, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 3518 Saint Blase Lane, St. Ann, MO 63074.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$290
Performed a furnace inspection and an AC system inspection.
- HVACWork status not resolved
Photograph shows a yellow corrugated flexible gas connector running from a fitting on a large appliance (furnace or boiler) to a black vertical gas pipe riser in a basement; the connector hangs in a loop and is secured to the riser with a clamp fitting.
- HVACWork status not resolved
Photograph shows furnace heat exchanger cells with visible rust, corrosion, and apparent cracking or deterioration on the metal clamshell surfaces, along with heavy dust accumulation throughout the furnace interior.
- HVACWork status not resolved
Photograph shows the interior panel of a gas furnace with a bilingual manufacturer's installation label detailing minimum clearance requirements to combustible materials for upflow, counterflow, and horizontal positions, chassis width part numbers (SBT 14, SBT 17, SBT 21), and compatibility with natural gas and propane.
- HVACWork status not resolved
Photograph shows the interior wiring compartment of an HVAC air handler or furnace with heavy dust and debris accumulation, a central contactor/relay component, a large disorganized bundle of multi-colored control wires, and a partially visible circuit board.
- HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge connected to an R22 refrigerant system, displaying evaporator-side pressure of 57.7 psi at 32.0°F and condenser-side pressure of 179.4 psi at 94.0°F.
- HVACWork status not resolved
the vent louvers show visible dust and debris accumulation
- HVACWork status not resolved
Photograph shows an outdoor AC condenser unit with the coil fins heavily packed with dirt, dust, lint, and organic debris visible through the louver grille, severely restricting airflow through the condenser.
- HVACWork status not resolved
Photograph shows an unfinished basement ceiling with a large black sheet-metal plenum connected to an air handler unit (partially labeled 'AF-100'), multiple round metal duct branches joined with Nashua 324A foil tape, and one large round duct with an open/uncapped end facing downward; exposed wood floor joists are visible above.
- HVACWork status not resolved