On July 24, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 7 other topics at 357 Fork Drive, St. Louis, MO 63137.
- Record date
Available findings
- SewerWork status not resolved
Sewer lateral inspection camera reached only approximately 8 feet before encountering a complete blockage from excessive scaling and/or soil; soil presence indicates a possible break in the line, and hydroflushing with re-scoping is recommended.
- PestWork status not resolved
WDI inspection found older termite damage on front landscape timbers; no evidence of live insects or damage elsewhere in the structure; recommendation to remove timbers or treat with a borate-based solution.
- ElectricalWork status not resolved
Most wiring is older aluminum and will likely need replacement; electric meter box has been cut and needs replaced; 125-amp GE panel in basement; smoke detectors missing or inoperable; no GFCI outlet present in kitchen.
- FoundationWork status not resolved
Basement moisture condition rated Wet; most moisture is attributed to broken windows and missing mortar in cinderblock walls — walls are in good shape overall but need cleaning and mortar touch-up.
- Home InspectionWork status not resolved
Whole-home inspection of 357 Fork Dr, Saint Louis, MO identified numerous deficiencies including lead supply pipes, a 50-year-old furnace with missing AC condenser, aluminum wiring, basement moisture, fire damage, mildew, and older termite damage; further specialist evaluations strongly recommended before closing.
- HVACWork status not resolved
Fedders gas furnace estimated 50 years old is missing parts and needs replacement; AC condenser is missing; HVAC ductwork is older and damaged and needs replacement.
- MoldWork status not resolved
Signs of mildew present on walls and ceilings throughout the interior, likely attributed to moisture intrusion from broken windows and excessive vegetation; fire damage with charred wood trim also noted in basement stairwell and kitchen area.
- PestWork status not resolved
Older termite damage observed on front landscape timbers; treatment recommended unless seller proves prior treatment — inspector suggests removing timbers or applying a borate-based solution such as Bora-Care.
- PlumbingWork status not resolved
Home was plumbed with lead supply pipes (small amount of PEX has been removed) and needs full replumbing with modern materials; water heater has been removed and needs replacement.
- RoofWork status not resolved
3-tab shingle roof estimated 5-10 years old is installed correctly but tree limbs dropping onto the roof are causing leaks; gutters are pulling away from the home, missing downspouts need replacement, and gutters are full of debris.
- WindowsWork status not resolved
Multiple broken and missing windows observed throughout the home; broken windows are a primary source of basement moisture intrusion and interior mildew growth.