← MAP

357 Fork Drive

St. Louis, MO 6313738.7454°N, 90.2093°W
1Event
Contributed by:1 contributor
SOURCE-BACKED RECORDS
Exterior of 357 Fork Drive

Property History Report

Negotiate this home like you've seen its receipts. You have.

Free right now · built from this home's 1 documented records

Fresh House Property Summary

Highlights selected from 1 documented record for this property.

  • Electrical
    Electrical · Aluminum wiring, cut meter box, and no smoke detectors found · 2026
  • HVAC
    HVAC · 50-year-old furnace needs replacement and AC condenser is missing · 2026
  • Sewer
    Sewer · Sewer line blocked at 8 feet with possible pipe break · 2026
  • Plumbing
    Plumbing · Lead supply pipes throughout home need full replumbing · 2026
  • Mold
    Mold · Mildew on walls and ceilings plus fire damage found in basement and kitchen · 2026
Ask this homePowered by Fresh House property intelligence®
Reading property memory…

RECORD SUMMARY

1 documented event
Contributed by: 1 contributor
First documented event: Jul 2026
Latest documented event: Jul 2026
First added to Fresh House: Jul 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 1 documented record for 357 Fork Drive, St. Louis, MO 63137, dated in July 2026.

Home Inspection

Home Inspection Document

Inspected Jul 24, 2026Uploaded Jul 28, 2026
Documented from uploaded report
Property Professional Uploaded

On July 24, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 7 other topics at 357 Fork Drive, St. Louis, MO 63137.

Scope
  • Electrical,
  • Foundation,
  • HVAC,
  • Home Inspection,
  • Mold,
  • Pest,
  • Plumbing,
  • Roof,
  • Sewer,
  • Windows
Contributor
worked on or inspected it
  • Home InspectionWhole-home inspection of 357 Fork Dr, Saint Louis, MO identified numerous deficiencies including lead supply pipes, a 50-year-old furnace with missing AC condenser, aluminum wiring, basement moisture, fire damage, mildew, and older termite damage; further specialist evaluations strongly recommended before closing.
  • SewerSewer lateral inspection camera reached only approximately 8 feet before encountering a complete blockage from excessive scaling and/or soil; soil presence indicates a possible break in the line, and hydroflushing with re-scoping is recommended.
  • PestWDI inspection found older termite damage on front landscape timbers; no evidence of live insects or damage elsewhere in the structure; recommendation to remove timbers or treat with a borate-based solution.

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

Home Inspection
✓ documented
Roof
✓ documented
Plumbing
✓ documented
Sewer
✓ documented
Foundation
✓ documented
Mold
✓ documented
Electrical
✓ documented
HVAC
✓ documented
Pest
✓ documented
Windows
✓ documented
Radon
undocumented
Appraisals
undocumented

Nearby homes with documented history