357 Fork Drive

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- Electrical · Aluminum wiring, cut meter box, and no smoke detectors found · 2026
- HVAC · 50-year-old furnace needs replacement and AC condenser is missing · 2026
- Sewer · Sewer line blocked at 8 feet with possible pipe break · 2026
- Plumbing · Lead supply pipes throughout home need full replumbing · 2026
- Mold · Mildew on walls and ceilings plus fire damage found in basement and kitchen · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 357 Fork Drive, St. Louis, MO 63137, dated in July 2026.
Home Inspection Document
On July 24, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 7 other topics at 357 Fork Drive, St. Louis, MO 63137.
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Mold,
- Pest,
- Plumbing,
- Roof,
- Sewer,
- Windows
- Home InspectionWhole-home inspection of 357 Fork Dr, Saint Louis, MO identified numerous deficiencies including lead supply pipes, a 50-year-old furnace with missing AC condenser, aluminum wiring, basement moisture, fire damage, mildew, and older termite damage; further specialist evaluations strongly recommended before closing.
- SewerSewer lateral inspection camera reached only approximately 8 feet before encountering a complete blockage from excessive scaling and/or soil; soil presence indicates a possible break in the line, and hydroflushing with re-scoping is recommended.
- PestWDI inspection found older termite damage on front landscape timbers; no evidence of live insects or damage elsewhere in the structure; recommendation to remove timbers or treat with a borate-based solution.
- ElectricalMost wiring is older aluminum and will likely need replacement; electric meter box has been cut and needs replaced; 125-amp GE panel in basement; smoke detectors missing or inoperable; no GFCI outlet present in kitchen.
- FoundationBasement moisture condition rated Wet; most moisture is attributed to broken windows and missing mortar in cinderblock walls — walls are in good shape overall but need cleaning and mortar touch-up.
- HVACFedders gas furnace estimated 50 years old is missing parts and needs replacement; AC condenser is missing; HVAC ductwork is older and damaged and needs replacement.
- MoldSigns of mildew present on walls and ceilings throughout the interior, likely attributed to moisture intrusion from broken windows and excessive vegetation; fire damage with charred wood trim also noted in basement stairwell and kitchen area.
- PestOlder termite damage observed on front landscape timbers; treatment recommended unless seller proves prior treatment — inspector suggests removing timbers or applying a borate-based solution such as Bora-Care.
- PlumbingHome was plumbed with lead supply pipes (small amount of PEX has been removed) and needs full replumbing with modern materials; water heater has been removed and needs replacement.
- Roof3-tab shingle roof estimated 5-10 years old is installed correctly but tree limbs dropping onto the roof are causing leaks; gutters are pulling away from the home, missing downspouts need replacement, and gutters are full of debris.
- WindowsMultiple broken and missing windows observed throughout the home; broken windows are a primary source of basement moisture intrusion and interior mildew growth.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,