3600 North Lindbergh Boulevard
Across 2 records on this property
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Fresh House Property Summary
Highlights selected from 2 documented records for this property.
- HVAC · AC system recharged with refrigerant and filter drier replaced · Jun 2026
- HVAC · Commercial HVAC diagnostic and refrigerant leak search performed · Jun 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 3600 North Lindbergh Boulevard, St. Ann, MO 63074, dated in June 2026. The amount summary includes $4,620 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Leak Search — Diagnostic and 1-hour refrigerant leak search
- HVAC
Built from Housecall Pro data
- $300HVACPerformed a commercial diagnostic service and a one-hour refrigerant leak search on the HVAC system.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an HVAC system, displaying R410A refrigerant with a low-side pressure of 130.8 psi, high-side pressure of 339.2 psi, and subcooling (SC) of 10.4°F; superheat (SH) reading is dashed/unavailable.
- HVACPhotograph shows an HVAC control board (part no. 25-2899-94, REV. K, RY11943) with a small LCD display indicating a maintenance alert message, multiple wiring harnesses connected, and visible dust accumulation on the board.
- HVACPhotograph shows an evaporator coil assembly with a large bundle of coiled copper refrigerant tubing, a thermostatic expansion valve (TXV) with brass body and gray sensing bulb, and aluminum fin coil face; copper lines show age-related oxidation patina.
- HVACmodel ZF180N30B2A1AAA1A1, serial N2A0541255, rated 300,000 BTU/HR total input, factory charged with R410A, 208/230; 3; 60V
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an outdoor HVAC unit, displaying R410A refrigerant pressures of 94.3 psi (SH side) and 94.9 psi (SC side).
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Refrigerant Service — 410-A refrigerant and filter drier service
- HVAC
Built from Housecall Pro data
- $4,320HVACSupplied 15 units of 410-A refrigerant and a 3/8" refrigerant filter drier, with journeyman and apprentice labor, AC materials (nitrogen, brazing rod, copper elbows and couplings, vacuum pump, recovery, flush), and transport, disposal and coil wash.
- HVACPhotograph shows a large fin-and-tube coil with multiple copper refrigerant lines, U-bend connections, pipe supports, and a service valve; copper piping displays significant oxidation and patina consistent with age.
- HVACPhotograph shows two Sporlan 'Catch-All' model C-164-S refrigerant filter-driers installed on copper refrigerant lines, rated for R134a, R22, R404A, R407C, R410A, and R507 refrigerants, with MRP 650 psig and MAP 700 psig pressure ratings.
- HVACPhotograph shows close-up of HVAC refrigerant coil U-bends with visible corrosion, dark oxidation discoloration, and a glistening wet spot indicating an apparent leak; caption states a patch is planned.
- HVACPhotograph shows copper refrigerant coil tubing with heavy oxidation, dark discoloration, and corrosion across multiple bends, with an oily or wet residue visible on the coil surfaces.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.