- HVAC · Furnace professionally maintained and cleaned · Nov 2025
- HVAC · HVAC maintenance plan visit completed at the property · Jul 2026
- HVAC · Full AC and furnace replacement estimated but not confirmed done · Jul 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 3 documented records for 3614 Kathleen Ann Drive, St. Louis, MO 63129, dated from November 2025 through July 2026. The amount summary includes $145 in completed work across HVAC, $9,871.65 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Furnace Maintenance — Furnace maintenance and cleaning
- HVAC
Built from Housecall Pro data
- $145HVACFurnace maintenance and cleaning performed.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Plan Visit — Residential maintenance plan visit #1
- HVAC
Built from Housecall Pro data
- HVACResidential Maintenance Plan visit #1 was performed at the service address.
- HVACPhotograph shows the electrical compartment of an outdoor HVAC unit with a cylindrical capacitor and surrounding wiring heavily covered in cobwebs, dust, and debris, indicating significant neglect and potential maintenance concern.
- HVACG-U 400072-12M, Serial No. Date 03-04) with an RPJ Heat Exchanger sticker affixed to the unit cabinet
- HVACPhotograph shows a manufacturer's data plate on a natural gas furnace rated at 75,000 BTU/hr input and 57,000 BTU/hr output, 120V/60Hz/1Ph, with visible rust staining on the unit housing near the upper right corner.
- HVAClower cabinet section bears additional labels service stickers visible on adjacent duct panel
- HVACPhotograph shows galvanized metal flue vent pipe rising vertically from a furnace unit through floor framing, with a horizontal branch connection at mid-height and visible rust/orange staining at the pipe junction.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an R22 refrigerant system, displaying low-side pressure of 63.8 psi with 16.2°F superheat and high-side pressure of 225.4 psi with 11.9°F subcooling.
- HVACPhotograph shows a gas furnace (brand label partially visible) and galvanized sheet-metal ductwork installed adjacent to the water heater in the same basement utility space.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an R22 refrigerant system, displaying low-side pressure of 62.4 psi, high-side pressure of 298.9 psi, superheat of 15.0°F, and subcooling of 26.4°F.
- HVACPhotograph shows an outdoor air conditioning condenser unit with condenser coil fins heavily packed with dirt, grass, and organic debris across the full circumference; weeds and vegetation are growing around the base of the unit.
- HVACPhotograph shows a close-up of a brass valve or fitting connected to copper tubing, exhibiting visible oxidation and corrosion on the brass body; a dark insulated pipe is visible adjacent to the fitting.
- HVACPhotograph shows the interior of an HVAC air handler or duct cabinet with visible dark staining or debris accumulation on interior surfaces, wooden frame rails, and reflective foil-faced ductwork or insulation visible at the base.
- HVACPhotograph shows a dual-run capacitor (45+5 μF, 440V, 50-60Hz) labeled AEROMET II, model M26P445WG3, mounted in a metal strap bracket inside an HVAC unit with visible wiring and accumulated dust/debris.
- HVACPhotograph shows exterior HVAC condenser unit with access panel open, revealing a large gray cylindrical capacitor, a contactor/relay, and multiple wires (red, yellow, blue) in heavily deteriorated condition with significant dirt, debris, and cobweb accumulation throughout the wiring compartment.
- HVACPhotograph shows a heavily soiled pleated air filter being removed from a furnace or air handler unit; filter media is visibly coated with dust and debris, and an airflow-direction arrow is printed on the blue cardboard frame.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Replacement Estimate — 2 options: 2.5-ton AC + 80K gas furnace
- HVAC
Options: 2.5-ton 14 SEER AC with Gas Furnace (80K) HE $10,056.50 · 13 SEER Ameristar AC & 80,000 BTU Furnace $9,871.65 (all expired)
Built from Housecall Pro data
- $9,872HVACEstimate for two expired HVAC replacement options: a 2.5-ton 14 SEER AC with 80K gas furnace, or a 13 SEER Ameristar AC with 80,000 BTU furnace, including coil, thermostat, flue pipe, and install materials.