HVACCompleted work
Residential Maintenance Plan visit #1 was performed at the service address.
HVACWork status not resolved
Photograph shows the electrical compartment of an outdoor HVAC unit with a cylindrical capacitor and surrounding wiring heavily covered in cobwebs, dust, and debris, indicating significant neglect and potential maintenance concern.
HVACWork status not resolved
G-U 400072-12M, Serial No. Date 03-04) with an RPJ Heat Exchanger sticker affixed to the unit cabinet
HVACWork status not resolved
Photograph shows a manufacturer's data plate on a natural gas furnace rated at 75,000 BTU/hr input and 57,000 BTU/hr output, 120V/60Hz/1Ph, with visible rust staining on the unit housing near the upper right corner.
HVACWork status not resolved
lower cabinet section bears additional labels service stickers visible on adjacent duct panel
HVACWork status not resolved
Photograph shows galvanized metal flue vent pipe rising vertically from a furnace unit through floor framing, with a horizontal branch connection at mid-height and visible rust/orange staining at the pipe junction.
HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge connected to an R22 refrigerant system, displaying low-side pressure of 63.8 psi with 16.2°F superheat and high-side pressure of 225.4 psi with 11.9°F subcooling.
HVACWork status not resolved
Photograph shows a gas furnace (brand label partially visible) and galvanized sheet-metal ductwork installed adjacent to the water heater in the same basement utility space.
HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge connected to an R22 refrigerant system, displaying low-side pressure of 62.4 psi, high-side pressure of 298.9 psi, superheat of 15.0°F, and subcooling of 26.4°F.
HVACWork status not resolved
Photograph shows an outdoor air conditioning condenser unit with condenser coil fins heavily packed with dirt, grass, and organic debris across the full circumference; weeds and vegetation are growing around the base of the unit.
HVACWork status not resolved
Photograph shows a close-up of a brass valve or fitting connected to copper tubing, exhibiting visible oxidation and corrosion on the brass body; a dark insulated pipe is visible adjacent to the fitting.
HVACWork status not resolved
Photograph shows the interior of an HVAC air handler or duct cabinet with visible dark staining or debris accumulation on interior surfaces, wooden frame rails, and reflective foil-faced ductwork or insulation visible at the base.
HVACWork status not resolved
Photograph shows a dual-run capacitor (45+5 μF, 440V, 50-60Hz) labeled AEROMET II, model M26P445WG3, mounted in a metal strap bracket inside an HVAC unit with visible wiring and accumulated dust/debris.
HVACWork status not resolved
HVACWork status not resolved
Photograph shows exterior HVAC condenser unit with access panel open, revealing a large gray cylindrical capacitor, a contactor/relay, and multiple wires (red, yellow, blue) in heavily deteriorated condition with significant dirt, debris, and cobweb accumulation throughout the wiring compartment.
HVACWork status not resolved
Photograph shows a heavily soiled pleated air filter being removed from a furnace or air handler unit; filter media is visibly coated with dust and debris, and an airflow-direction arrow is printed on the blue cardboard frame.