366 Greycliff Bluff Drive
Across 3 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 3 documented records
Fresh House Property Summary
Highlights selected from 3 documented records for this property.
- HVAC · New furnace installed · Jan 2025$9k
- HVAC · Furnace serviced under a maintenance plan · Oct 2026
- HVAC · Air conditioner serviced under a maintenance plan · Apr 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 3 documented records for 366 Greycliff Bluff Drive, St. Louis, MO 63129, dated in January 2025. The amount summary includes $8,990 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Furnace Installation — New furnace installation
- HVAC
Built from Housecall Pro data
- $8,990HVACNew furnace installation performed at 366 Greycliff Bluff Drive.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Invoice — Air conditioning maintenance visit
- HVAC
Built from Housecall Pro data
- HVACAir Conditioning Maintenance performed under the Residential Maintenance Plan.
- HVACPhotograph shows a Klein Tools CL390 digital clamp meter displaying a capacitance reading of 04.3 μF, being used near an HVAC condenser unit with an orange fan blade visible in the background.
- HVACinstall prohibited in Southwest
- HVACPhotograph shows a True RMS 400A AC/DC digital clamp meter displaying a reading of 00.25 AC amps, being used near an exterior electrical service entrance or panel on a residential property.
- HVACPhotograph shows the louvered side panel of an outdoor HVAC condenser unit with aluminum coil fins visible behind white painted metal louvers; fins appear intact and free of visible debris or significant damage.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an outdoor R410A condenser unit, displaying superheat of 14.3°F, subcooling of 12.6°F, low-side pressure of 114.0 psi, and high-side pressure of 299.5 psi.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an outdoor HVAC condensing unit, displaying R410A refrigerant readings: superheat (SH) 17.2°F, subcooling (SC) 12.2°F, low-side pressure 109.2 psi, and high-side pressure 269.3 psi.
- HVACPhotograph shows an exterior HVAC condenser unit with refrigerant lines (copper tubing with insulation) and electrical wiring at the building exterior, alongside a white louvered wall vent cap mounted on white vinyl siding; a partial electrical warning label is visible on the condenser unit.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying R410A refrigerant readings: evaporator saturation 38.0°F at 114.1 psi (low side) and condenser saturation 95.8°F at 299.9 psi (high side).
- HVACthe meter dial is set to the 400A AC range
- HVACPhotograph shows a white radial fan grille on an HVAC unit with heavily soiled, debris-laden surface visible behind the grille slats, indicating significant dust and lint accumulation.
- HVACPhotograph shows the open electrical compartment of an outdoor HVAC condenser unit with multiple colored wires connected to a terminal block/contactor, a cylindrical capacitor in the upper right, and significant dust and lint accumulation on the wiring shelf and components; some wiring appears loosely coiled on the shelf.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying R410A refrigerant readings: evaporator side 35.8°F / 109.2 psi and condenser side 88.4°F / 268.9 psi.
- HVACPhotograph shows a copper water supply pipe running vertically through floor joists and connecting to a gate-style shutoff valve; dark staining is visible on the underside of the wood floor joists in the surrounding area, and a white PVC pipe is visible along the right side of the frame.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Maintenance — Furnace maintenance under maintenance plan
- HVAC
Built from Housecall Pro data
- HVACFurnace maintenance was performed under the Residential Maintenance Plan.
- HVACPhotograph shows a red ThermoPro digital instant-read thermometer with probe extended, resting against a stainless steel surface that appears to be refrigeration or cooling equipment, with shelving visible in the background.
- HVACPhotograph shows a Fluke 323 True RMS Clamp Meter displaying a reading of 1.6 A AC, positioned at an electrical panel or equipment enclosure with multiple visible wires.
HVAC
HVAC
HVACOnly original contributor can modify this entry