HVACCompleted work
Air Conditioning Maintenance performed under the Residential Maintenance Plan.
HVACWork status not resolved
Photograph shows a Klein Tools CL390 digital clamp meter displaying a capacitance reading of 04.3 μF, being used near an HVAC condenser unit with an orange fan blade visible in the background.
HVACWork status not resolved
install prohibited in Southwest
HVACWork status not resolved
Photograph shows a True RMS 400A AC/DC digital clamp meter displaying a reading of 00.25 AC amps, being used near an exterior electrical service entrance or panel on a residential property.
HVACWork status not resolved
Photograph shows the louvered side panel of an outdoor HVAC condenser unit with aluminum coil fins visible behind white painted metal louvers; fins appear intact and free of visible debris or significant damage.
HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge connected to an outdoor R410A condenser unit, displaying superheat of 14.3°F, subcooling of 12.6°F, low-side pressure of 114.0 psi, and high-side pressure of 299.5 psi.
HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge connected to an outdoor HVAC condensing unit, displaying R410A refrigerant readings: superheat (SH) 17.2°F, subcooling (SC) 12.2°F, low-side pressure 109.2 psi, and high-side pressure 269.3 psi.
HVACWork status not resolved
Photograph shows an exterior HVAC condenser unit with refrigerant lines (copper tubing with insulation) and electrical wiring at the building exterior, alongside a white louvered wall vent cap mounted on white vinyl siding; a partial electrical warning label is visible on the condenser unit.
HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying R410A refrigerant readings: evaporator saturation 38.0°F at 114.1 psi (low side) and condenser saturation 95.8°F at 299.9 psi (high side).
HVACWork status not resolved
the meter dial is set to the 400A AC range
HVACWork status not resolved
Photograph shows a white radial fan grille on an HVAC unit with heavily soiled, debris-laden surface visible behind the grille slats, indicating significant dust and lint accumulation.
HVACWork status not resolved
Photograph shows the open electrical compartment of an outdoor HVAC condenser unit with multiple colored wires connected to a terminal block/contactor, a cylindrical capacitor in the upper right, and significant dust and lint accumulation on the wiring shelf and components; some wiring appears loosely coiled on the shelf.
HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying R410A refrigerant readings: evaporator side 35.8°F / 109.2 psi and condenser side 88.4°F / 268.9 psi.
HVACWork status not resolved
HVACWork status not resolved
Photograph shows a copper water supply pipe running vertically through floor joists and connecting to a gate-style shutoff valve; dark staining is visible on the underside of the wood floor joists in the surrounding area, and a white PVC pipe is visible along the right side of the frame.