- HVAC · AC service found failed compressor and bad control board · Jul 2025
- HVAC · Furnace and condenser replacement recommended due to rust · Jul 2025
- HVAC · Separate service call performed for mold coming from vents · Oct 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 3833 Mcree Avenue, St. Louis, MO 63110, dated in October 2025. The amount summary includes $275.50 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Diagnostic Service Call — Bad compressor and board
- HVAC
Built from Housecall Pro data
- $187HVACService call for AC not working: found water in and around the furnace/coil, bad control board needing replacement, and a failed compressor; blower was hard wired to circulate air, and furnace and condenser replacement was recommended due to unsafe rust.
- HVACPhotograph shows a furnace cabinet with extensive moisture and water droplets visible on the exterior surfaces, including the top panel and front face; a flue duct with foil tape is visible at the top, also showing condensation; a carbon monoxide poisoning hazard warning label is affixed to the lower front panel.
- HVACPhotograph shows a Fieldpiece SMAN Refrigerant Manifold gauge connected to an outdoor condenser unit displaying R410A readings: low side 223.7 Psig, high side 214.1 Psig, superheat 16.1 SH, subcooling -16.1 SC flagged as Below Typical Range, VSAT 76.5, LSAT 73.6, ODDB 94.3, SLT 92.6.
- HVACPhotograph shows heavy condensation covering the underside of the subfloor or foil-faced surface in a basement/crawlspace, with moisture staining visible along the base of the painted stone or concrete-block foundation walls and a small basement window visible on the right.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Service call for mold coming from vents
- HVAC
Built from Housecall Pro data
- $89HVACNormal hours service call performed for mold coming from vents.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.