HVAC Diagnostic Service Call — Bad compressor and board
- HVAC
On July 29, 2025, ASSURED HEATING AND COOLING documented HVAC at 3833 Mcree Avenue, St. Louis, MO 63110.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$187
Service call for AC not working: found water in and around the furnace/coil, bad control board needing replacement, and a failed compressor; blower was hard wired to circulate air, and furnace and condenser replacement was recommended due to unsafe rust.
- HVACWork status not resolved
Photograph shows a furnace cabinet with extensive moisture and water droplets visible on the exterior surfaces, including the top panel and front face; a flue duct with foil tape is visible at the top, also showing condensation; a carbon monoxide poisoning hazard warning label is affixed to the lower front panel.
- HVACWork status not resolved
Photograph shows a Fieldpiece SMAN Refrigerant Manifold gauge connected to an outdoor condenser unit displaying R410A readings: low side 223.7 Psig, high side 214.1 Psig, superheat 16.1 SH, subcooling -16.1 SC flagged as Below Typical Range, VSAT 76.5, LSAT 73.6, ODDB 94.3, SLT 92.6.
- HVACWork status not resolved
Photograph shows heavy condensation covering the underside of the subfloor or foil-faced surface in a basement/crawlspace, with moisture staining visible along the base of the painted stone or concrete-block foundation walls and a small basement window visible on the right.
- HVACWork status not resolved