← MAP

4 Chestnut Circle

Florissant, MO 6303338.7967°N, 90.3073°W
2Events
Contributed by:1 contributor
SOURCE-BACKED RECORDS

Property History Report

Negotiate this home like you've seen its receipts. You have.

Free right now · built from this home's 2 documented records

Fresh House Property Summary

Highlights selected from 2 documented records for this property.

  • HVAC
    HVAC · Furnace panels opened and interior components visibly inspected · 2026
  • HVAC
    HVAC · Furnace data plate shows manufacture date of April 2018 · 2026
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 4 Chestnut Circle. I only speak from this property's source-backed records — 2 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

2 documented events
Contributed by: 1 contributor
First documented event: Apr 2026
Latest documented event: Apr 2026
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 2 documented records for 4 Chestnut Circle, Florissant, MO 63033, dated in April 2026.

HVAC

HVAC Maintenance Plan Visit — Maintenance plan visit #1

Document dated Apr 15, 2026Uploaded Nov 8, 20264 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 4 Chestnut Circle, Florissant, MO 63033.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

  • HVACVisit #1 under the Residential Maintenance Plan was performed at 4 Chestnut Circle.
  • HVACliquid pressure 250.8 psig, liquid temp 67.8°F, liquid saturation 83.7°F, actual subcooling 15.9°F, discharge pressure 117.4 psig
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Maintenance Plan Visit — Maintenance plan visit #2

Document dated Oct 8, 2026Uploaded Nov 8, 20269 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 4 Chestnut Circle, Florissant, MO 63033.
Scope
  • HVAC

Built from Housecall Pro data

  • HVACVisit #2 of the Residential Maintenance Plan was performed at the property.
  • HVACTUD2B080ACV32BA, Serial No. 18173NKA1G, manufactured April 2018, rated at 80,000 BTU/HR high input and 52,000 BTU/HR low input
  • HVACa borescope inspection camera, drill, and other tools are visible on the floor nearby, and replacement air filters are leaning against the wall to the right
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC
+4

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Plumbing
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby homes with documented history