On August 5, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 4065 Schiller Place, St. Louis, MO 63116.
- Record date
Available findings
- PestWork status not resolved
Visual inspection of SFR at 4065 Schiller Place found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or wood boring beetles); no treatment recommended.
- ElectricalWork status not resolved
Federal Pacific fuse box (last inspected 1977) requires update; knob-and-tube wiring still present throughout but could not be tested due to no power; 100-amp service; smoke detectors missing throughout home including near basement gas appliances.
- FoundationWork status not resolved
Large cracks in basement walls require sealing with epoxy injections to prevent moisture intrusion; exterior basement finished wall cracks also noted; no moisture detected at time of inspection.
- Home InspectionWork status not resolved
Whole-home inspection at 4065 Schiller Pl identified multiple deficiencies including a safety-hazard electrical system, full HVAC replacement needed, corroded plumbing supply lines, basement wall cracks, and window defects; no structural issues found.
- HVACWork status not resolved
RPJ gas furnace estimated 40 years old is heavily rusted and requires replacement; AC condenser has been removed and is not present; full HVAC system replacement recommended.
- PlumbingWork status not resolved
Small section of water supply lines is galvanized steel and heavily corroded/rusted, requiring replacement; Reliance 40-gallon natural gas water heater (manufactured 2014) is functional but missing the TPR valve discharge pipe, which must be replaced.
- RoofWork status not resolved
Architectural shingle roof estimated 2-5 years old and in satisfactory condition; loose gutter downspout and fascia panel at rear patio need securing; missing soffit panels need replacement.
- WindowsWork status not resolved
Rear-facing second-floor window is out of frame and needs to be reset; three missing window panes at rear of home require replacement; rear patio door is missing and must be replaced.