Property records for 4065 Schiller Place, St. Louis, MO 63116

All 1 public upload record returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 1.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

Document (08/07/2026)

  • Electrical
  • Foundation
  • HVAC
  • Home Inspection
  • Pest
  • Plumbing
  • Roof
  • Windows

On August 5, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 4065 Schiller Place, St. Louis, MO 63116.

Record date

Available findings

  • PestWork status not resolved

    Visual inspection of SFR at 4065 Schiller Place found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or wood boring beetles); no treatment recommended.

  • ElectricalWork status not resolved

    Federal Pacific fuse box (last inspected 1977) requires update; knob-and-tube wiring still present throughout but could not be tested due to no power; 100-amp service; smoke detectors missing throughout home including near basement gas appliances.

  • FoundationWork status not resolved

    Large cracks in basement walls require sealing with epoxy injections to prevent moisture intrusion; exterior basement finished wall cracks also noted; no moisture detected at time of inspection.

  • Home InspectionWork status not resolved

    Whole-home inspection at 4065 Schiller Pl identified multiple deficiencies including a safety-hazard electrical system, full HVAC replacement needed, corroded plumbing supply lines, basement wall cracks, and window defects; no structural issues found.

  • HVACWork status not resolved

    RPJ gas furnace estimated 40 years old is heavily rusted and requires replacement; AC condenser has been removed and is not present; full HVAC system replacement recommended.

  • PlumbingWork status not resolved

    Small section of water supply lines is galvanized steel and heavily corroded/rusted, requiring replacement; Reliance 40-gallon natural gas water heater (manufactured 2014) is functional but missing the TPR valve discharge pipe, which must be replaced.

  • RoofWork status not resolved

    Architectural shingle roof estimated 2-5 years old and in satisfactory condition; loose gutter downspout and fascia panel at rear patio need securing; missing soffit panels need replacement.

  • WindowsWork status not resolved

    Rear-facing second-floor window is out of frame and needs to be reset; three missing window panes at rear of home require replacement; rear patio door is missing and must be replaced.