Hi, I'm 4065 Schiller Place. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
← MAPSOURCE-BACKED RECORDS
4065 Schiller Place
St. Louis, MO 6311638.5761°N, 90.2638°W
1Event
Contributed by:1 contributor

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- Electrical · Outdated fuse box, knob-and-tube wiring, and missing smoke detectors found · 2026
- HVAC · 40-year-old rusted furnace and missing AC unit need full replacement · 2026
- Foundation · Large cracks in basement walls need sealing to prevent moisture · 2026
- Plumbing · Heavily corroded supply lines and missing water heater safety pipe found · 2026
- Roof · Roof is 2-5 years old and in satisfactory condition · 2026
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
1 documented event
Contributed by: 1 contributor
First documented event: Aug 2026
Latest documented event: Aug 2026
First added to Fresh House: Aug 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 1 documented record for 4065 Schiller Place, St. Louis, MO 63116, dated in August 2026.
Home Inspection
Home Inspection Document
Inspected Aug 5, 2026Uploaded Aug 8, 20262 files
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 5 other topics at 4065 Schiller Place, St. Louis, MO 63116.
Scope
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Windows
Contributor
worked on or inspected it- Home InspectionWhole-home inspection at 4065 Schiller Pl identified multiple deficiencies including a safety-hazard electrical system, full HVAC replacement needed, corroded plumbing supply lines, basement wall cracks, and window defects; no structural issues found.
- PestVisual inspection of SFR at 4065 Schiller Place found no visible evidence of wood destroying insects (termites, carpenter ants, carpenter bees, or wood boring beetles); no treatment recommended.
- ElectricalFederal Pacific fuse box (last inspected 1977) requires update; knob-and-tube wiring still present throughout but could not be tested due to no power; 100-amp service; smoke detectors missing throughout home including near basement gas appliances.
- FoundationLarge cracks in basement walls require sealing with epoxy injections to prevent moisture intrusion; exterior basement finished wall cracks also noted; no moisture detected at time of inspection.
- HVACRPJ gas furnace estimated 40 years old is heavily rusted and requires replacement; AC condenser has been removed and is not present; full HVAC system replacement recommended.
- PlumbingSmall section of water supply lines is galvanized steel and heavily corroded/rusted, requiring replacement; Reliance 40-gallon natural gas water heater (manufactured 2014) is functional but missing the TPR valve discharge pipe, which must be replaced.
- RoofArchitectural shingle roof estimated 2-5 years old and in satisfactory condition; loose gutter downspout and fascia panel at rear patio need securing; missing soffit panels need replacement.
- WindowsRear-facing second-floor window is out of frame and needs to be reset; three missing window panes at rear of home require replacement; rear patio door is missing and must be replaced.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedWindows
✓ documentedSewer
undocumentedMold
undocumentedRadon
undocumentedAppraisals
undocumented