Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 41 Old Yorktown Court, Wentzville, MO 63385.
Available findings
- ElectricalWork status not resolved
GFCI outlet protection is not present in the laundry room and must be installed.
- FoundationWork status not resolved
Carbon fiber and epoxy repairs are present on basement walls and appear professionally made and effective; common hairline cracks also observed but not large enough to require repair, and no moisture intrusion was detected.
- Home InspectionWork status not resolved
Whole-home inspection of a single-family property found the home in generally great condition with no structural issues; four deficiencies were identified across plumbing, foundation, and electrical systems.
- HVACWork status not resolved
digital thermostat in hallway is satisfactory
- PlumbingWork status not resolved
gas inspection found aluminum exhaust pipe on water heater must be replaced with galvanized pipe, and a cracked section of pipe on the gas furnace in the basement also requires replacement
- RoofWork status not resolved
Gable roof with 3-year-old architectural shingles inspected by drone; condition is satisfactory with proper installation; flashings, gutters, soffit, fascia, and ventilation all satisfactory.
- HVACWork status not resolved
Gas appliance inspection found insufficient combustion air for furnace and water heater, non-compliant aluminum flue requiring replacement with galvanized, cracked/corroded swivel T, gas meter within 36 inches of electrical service (safety hazard), unsecured thermal expansion tank, unmarked copper gas lines, and condenser with rusty capacitor and improperly attached wire conduit; furnace combustion analyzer test passed with no heat exchanger crack detected.
- SewerWork status not resolved
Sewer lateral is open and flowing with no damages and no obstructions observed; line is comprised of PVC from the basement stack to the city sewer tie-in.
- PestWork status not resolved
no action or treatment recommended