Hi, I'm 41 Old Yorktown Court. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
← MAPSOURCE-BACKED RECORDS
41 Old Yorktown Court
Wentzville, MO 6338538.8270°N, 90.8747°W
1Event
Contributed by:1 contributor

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · Gas meter too close to electrical service, a safety hazard · 2026
- HVAC · Furnace and water heater have multiple ventilation and gas line issues · 2026
- Electrical · Laundry room lacks required safety outlet protection · 2026
- Foundation · Basement walls have professional crack repairs with no moisture found · 2026
- Plumbing · Water heater and furnace exhaust pipes need replacement · 2026
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
1 documented event
Contributed by: 1 contributor
First added to Fresh House: Sep 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 1 documented record for 41 Old Yorktown Court, Wentzville, MO 63385.
DOCUMENTED
Home Inspection
Uploaded Sep 7, 20264 files
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 5 other topics at 41 Old Yorktown Court, Wentzville, MO 63385.
Scope
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Sewer
- Home InspectionWhole-home inspection of a single-family property found the home in generally great condition with no structural issues; four deficiencies were identified across plumbing, foundation, and electrical systems.
- ElectricalGFCI outlet protection is not present in the laundry room and must be installed.
- FoundationCarbon fiber and epoxy repairs are present on basement walls and appear professionally made and effective; common hairline cracks also observed but not large enough to require repair, and no moisture intrusion was detected.
- HVACdigital thermostat in hallway is satisfactory
- Plumbinggas inspection found aluminum exhaust pipe on water heater must be replaced with galvanized pipe, and a cracked section of pipe on the gas furnace in the basement also requires replacement
- RoofGable roof with 3-year-old architectural shingles inspected by drone; condition is satisfactory with proper installation; flashings, gutters, soffit, fascia, and ventilation all satisfactory.
- HVACGas appliance inspection found insufficient combustion air for furnace and water heater, non-compliant aluminum flue requiring replacement with galvanized, cracked/corroded swivel T, gas meter within 36 inches of electrical service (safety hazard), unsecured thermal expansion tank, unmarked copper gas lines, and condenser with rusty capacitor and improperly attached wire conduit; furnace combustion analyzer test passed with no heat exchanger crack detected.
- SewerSewer lateral is open and flowing with no damages and no obstructions observed; line is comprised of PVC from the basement stack to the city sewer tie-in.
- Pestno action or treatment recommended
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedSewer
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedMold
undocumentedRadon
undocumentedAppraisals
undocumentedWindows
undocumented