- HVAC · Outdoor AC unit had shorted wires and blown dual run capacitor replaced · May 2022
- HVAC · Outdoor unit cleaned and system recharged with R-22 refrigerant · Jul 2022
- HVAC · Indoor coil was found clogged and filter was changed · Jul 2022
- HVAC · Air conditioner received a tune-up service · Aug 2023
RECORD SUMMARY
1 permit record on this page come from the City of St. Louis permit database. Community records come from 1 contributor.
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 4 documented records for 4119 POTOMAC, St. Louis, MO, dated from July 2018 through August 2023. The amount summary includes $887.84 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Capacitor Repair — Blown capacitor replaced, wires repaired
- HVAC
Built from Housecall Pro data
- $332HVACFound wires shorted off the capacitor on the outdoor unit; repaired wires, replaced blown dual run capacitor, cleaned outdoor unit, and checked system charge, with all systems working as intended.
- HVACPhotograph shows a round HVAC run capacitor with visibly scorched, burned terminals and corrosion, with multiple wires (black, purple, orange, yellow) connected; the capacitor body and terminal area exhibit heat damage and debris consistent with a failed or failing component.
- HVACPhotograph shows the open electrical compartment of an outdoor HVAC condensing unit with a cylindrical run capacitor, a hard start capacitor kit (labeled 'START / HARD START CAPACITOR'), a contactor relay, and multiple wiring leads; the compartment exhibits heavy dust, debris, and cobwebs, and a pink service sticker partially reading 'RUN TESTED BY' is visible on the unit casing.
- HVACPhotograph shows a cylindrical HVAC run capacitor with multiple colored wires (brown, orange, yellow, purple) connected to its terminals; one terminal exhibits visible burn damage and charring, indicating capacitor failure.
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — System low on R-22; recharged to specs
- HVAC
Built from Housecall Pro data
- $437HVACService call found outdoor unit dirty and indoor coil clogged; changed filter, cleaned outdoor unit, and charged the low system with R-22 to specs so all systems worked as intended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Tune-Up — A/C tune up
- HVAC
Built from Housecall Pro data
- $120HVACPerformed an air conditioner A/C tune up.
Only original contributor can modify this entry
Create an account to manage your contributions over time
AE Permit AE-2018-144291
On July 23, 2018, City of St. Louis documented Electrical at 4119 POTOMAC, St. Louis, MO.
Declared on the permit, not confirmed spending or proof of completed work.
Obtained from a public records source; may contain reporting delays or errors.
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.