Property records for 4127 Oregon Avenue, St. Louis, MO 63118

All 4 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 4.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Service Call — Trip fee and residential labor

  • HVAC

On August 25, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4127 Oregon Avenue, St. Louis, MO 63118.

Record date

Available findings

  • HVACCompleted work$219

    Trip fee and residential labor (non-member) provided at the service address.

  • HVACWork status not resolved

    Photograph shows a Rheem forced-air furnace data plate with model number RB01SA075317MSA, serial number W051831048, manufactured 02/2018, rated at 70,000 BTU/hr maximum input, configured for natural gas.

  • HVACWork status not resolved

    Photograph shows the manufacturer data plate on a Rheem forced-air natural gas furnace, model R801SA075317MSA, serial W051831048, manufactured 02/2018, rated at 75,000 BTU/hr maximum input, factory equipped for natural gas.

  • HVACWork status not resolved

    Photograph shows a UEi EM152 digital manometer connected via tubing to a furnace/air handler unit, with the display reading approximately 0.017; iron pipes and furnace wiring are visible in the background.

  • HVACWork status not resolved

    Vacancy visit identified that AC is functional but heat is not responding at 4127 Oregon Ave Unit 2F, St. Louis, MO 63118.

  • HVACWork status not resolved

    Photograph shows four gas meters mounted on a stone masonry wall within a wood-framed alcove, connected by black iron gas supply pipes, valves, and flexible connectors; the installation appears to serve multiple units.

  • HVACWork status not resolved

    Photograph shows a gas meter assembly mounted in a basement against an aged stone/brick wall, with a cast-iron meter body, horizontal supply pipe, brass union fittings, a flexible corrugated stainless steel connector, a black flexible hose, and a bonding/grounding clamp with an orange label attached to the pipe.

  • HVACWork status not resolved
Record 2Public property record

HVAC Maintenance Service — Return trip and 1.2 hrs maintenance labor

  • HVAC

On September 2, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4127 Oregon Avenue, St. Louis, MO 63118.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$231

    Performed a return trip and 1.2 hours of residential maintenance labor.

  • HVACWork status not resolved

    Fieldpiece app screenshot shows manometer P1 reading of 4.07 inWC; P2 sensor not linked, Delta P not calculated; air side capacity airflow not entered and return/supply dry and wet bulb temperatures not linked.

  • HVACWork status not resolved

    Photograph shows a close-up of a sealed metal HVAC equipment panel (part no. AS38844) with an embossed caution label instructing that the gasket must be replaced if the panel is removed; fiberglass insulation and foil-faced duct wrap are visible surrounding the panel, and a square access port is visible at the panel center.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with the access panel open, revealing active blue burner flames across multiple burners, a black gas crossover/manifold bar, wiring harnesses, and a control system label reading 'RB01SA075317MSA / W051831048 / CONTROL SYSTEM'.

  • HVACWork status not resolved

    Photograph shows the interior burner compartment of a gas furnace with multiple burners actively firing, visible heat exchanger sections, associated wiring, and a blower motor assembly.

  • HVACWork status not resolved

    Photograph shows a Fieldpiece app measurements screen with manometer P1 reading 3.45 inWC, system mode set to COOL; P2, Delta P, airflow, capacity, and air-side temperature fields are blank or awaiting linked tools.

  • HVACWork status not resolved
  • HVACWork status not resolved

    Photograph shows an active gas burner flame visible through a square furnace sight glass or inspection port, with orange/yellow flame at center and blue flame at the base, indicating the burner is in operation.

  • HVACWork status not resolved

    Photograph shows a gas burner port actively firing, with an orange/yellow flame in the upper portion and blue flame pattern in the lower portion, photographed in a dark enclosure.

Record 3Public property record

HVAC Warranty Callback — Warranty callback, Merv 11 filter supplied

  • HVAC

On September 4, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4127 Oregon Avenue, St. Louis, MO 63118.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$20

    Warranty callback service visit performed and a 16/25/1 Merv 11 filter supplied.

  • HVACWork status not resolved

    Photograph shows a heavily corroded metal electrical junction box with a toggle switch (labeled OFF, rated 5A/250V) and exposed wiring including a wire nut, with flexible metallic conduit and rigid conduit entries; the box and internal components exhibit significant rust and deterioration.

  • HVACWork status not resolved

    Photograph shows a Braeburn programmable thermostat mounted on a wall, displaying a room temperature of 89°F with a set point of 75°F; the system is in COOL mode with 'COOL ON' active and the fan set to AUTO.

  • HVACWork status not resolved

    Photograph shows a Braeburn programmable thermostat displaying a room temperature of 89°F against a set point of 75°F, with the system in COOL mode and status reading COOL ON, indicating the cooling system is actively running but the space is significantly above the set point.

  • HVACWork status not resolved

    the system is in Cool mode with 'COOL ON' active and the fan set to Auto

  • HVACWork status not resolved

    High-priority work order to assess and repair a thermostat error for the AC at unit 2F, with a maintenance limit of $500.

  • HVACWork status not resolved

    Photograph shows a Braeburn programmable thermostat mounted on a wall displaying a room temperature of 89°F, a cooling set-point of 73°F, with 'COOL ON' active, fan set to AUTO, and time reading 2:02 PM on Thursday.

  • HVACWork status not resolved

    Photograph shows a 16x25x1 pleated HVAC air filter with heavily accumulated dust and debris across the filter media, indicating the filter is significantly soiled and due for replacement.

  • HVACWork status not resolved

    Photograph shows the interior of a furnace cabinet with a control board (Model 1194-200, part 62-104058-02) displaying a red LED error code 'E,' with multiple wiring harnesses connected and a relay component visible.

Record 4Public property record

HVAC Capacitor Replacement — Dual capacitor replaced; 2 pole contactor

  • HVAC

On September 18, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4127 Oregon Avenue, St. Louis, MO 63118.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$494

    Performed residential diagnostic service, replaced dual capacitor, and supplied a 2 pole contactor (24V, 40 Amp).

  • HVACWork status not resolved

    Photograph shows an HVAC contactor with heavily pitted and burned contact points, yellow and brown wires connected to terminals, and a red wire nut; the contactor label partially reads 'PER POLE / LRA / RES / 40'.

  • HVACWork status not resolved

    Photograph shows the interior electrical compartment of an outdoor HVAC condenser unit, with a cylindrical run capacitor and a contactor relay visible, connected by multiple colored wires (yellow, orange, red, purple, gray, green); dirt and debris are present on the unit's base pan.

  • HVACWork status not resolved

    Photograph shows a Rheem outdoor condenser unit data plate: Model RA1324AJ1NA, Serial W331748361, manufactured 08/2017, 208/230V single-phase, R410A refrigerant, assembled in Mexico.

  • HVACWork status not resolved

    Photograph shows a Yellow Jacket brass test and charging manifold with two refrigerant pressure gauges (blue low-side and red high-side), calibrated for R-22 and R-410A refrigerants, lying on the ground among leaf debris.