← MAP

4127 Oregon Avenue

St. Louis, MO 6311838.5807°N, 90.2342°W
4Events
Contributed by:1 contributor
$964Documented amounts
SOURCE-BACKED RECORDS

Across 4 records on this home

Completed work

Invoices and paid receipts

$745

Estimated · not confirmed

Quotes, estimates, and other amounts not confirmed as performed

$219

Property History Report

Negotiate this home like you've seen its receipts. You have.

Free right now · built from this home's 4 documented records

Fresh House Property Summary

Highlights selected from 4 documented records for this property.

  • HVAC
    HVAC · AC outdoor unit diagnosed; dual capacitor and contactor replaced · Sep 2026
  • HVAC
    HVAC · Return maintenance visit performed with additional labor · Sep 2026
  • HVAC
    HVAC · Heat not responding at the unit noted during a vacancy visit · Aug 2026
  • HVAC
    HVAC · Thermostat error on AC at unit 2F flagged for assessment and repair · Sep 2026
  • HVAC
    HVAC · Gas furnace manufactured February 2018 is present at the property · 2026
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 4127 Oregon Avenue. I only speak from this property's source-backed records — 4 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

4 documented events
Contributed by: 1 contributor
First documented event: Aug 2026
Latest documented event: Sep 2026
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 4 documented records for 4127 Oregon Avenue, St. Louis, MO 63118, dated from August 2026 through September 2026. The amount summary includes $745 in completed work across HVAC, $219 in estimates; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Service Call — Trip fee and residential labor

Document dated Aug 25, 2026Uploaded Nov 8, 20268 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 4127 Oregon Avenue, St. Louis, MO 63118.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $219
  • HVACTrip fee and residential labor (non-member) provided at the service address.
    $219
  • HVACPhotograph shows a Rheem forced-air furnace data plate with model number RB01SA075317MSA, serial number W051831048, manufactured 02/2018, rated at 70,000 BTU/hr maximum input, configured for natural gas.
  • HVACPhotograph shows the manufacturer data plate on a Rheem forced-air natural gas furnace, model R801SA075317MSA, serial W051831048, manufactured 02/2018, rated at 75,000 BTU/hr maximum input, factory equipped for natural gas.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC
+3

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Maintenance Service — Return trip and 1.2 hrs maintenance labor

Document dated Sep 2, 2026Uploaded Nov 8, 20269 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 4127 Oregon Avenue, St. Louis, MO 63118.
Scope
  • HVAC
Outcome
Paid in full

Built from Housecall Pro data

Total documented value on this timeline entry: $231
  • HVACPerformed a return trip and 1.2 hours of residential maintenance labor.
    $231
  • HVACFieldpiece app screenshot shows manometer P1 reading of 4.07 inWC; P2 sensor not linked, Delta P not calculated; air side capacity airflow not entered and return/supply dry and wet bulb temperatures not linked.
  • HVACPhotograph shows a close-up of a sealed metal HVAC equipment panel (part no. AS38844) with an embossed caution label instructing that the gasket must be replaced if the panel is removed; fiberglass insulation and foil-faced duct wrap are visible surrounding the panel, and a square access port is visible at the panel center.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC
+4

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Warranty Callback — Warranty callback, Merv 11 filter supplied

Document dated Sep 4, 2026Uploaded Nov 8, 20269 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 4127 Oregon Avenue, St. Louis, MO 63118.
Scope
  • HVAC
Outcome
Paid in full

Built from Housecall Pro data

Total documented value on this timeline entry: $20
  • HVACWarranty callback service visit performed and a 16/25/1 Merv 11 filter supplied.
    $20
  • HVACPhotograph shows a heavily corroded metal electrical junction box with a toggle switch (labeled OFF, rated 5A/250V) and exposed wiring including a wire nut, with flexible metallic conduit and rigid conduit entries; the box and internal components exhibit significant rust and deterioration.
  • HVACPhotograph shows a Braeburn programmable thermostat mounted on a wall, displaying a room temperature of 89°F with a set point of 75°F; the system is in COOL mode with 'COOL ON' active and the fan set to AUTO.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC
+4

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Capacitor Replacement — Dual capacitor replaced; 2 pole contactor

Document dated Sep 18, 2026Uploaded Nov 8, 20265 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 4127 Oregon Avenue, St. Louis, MO 63118.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $494
  • HVACPerformed residential diagnostic service, replaced dual capacitor, and supplied a 2 pole contactor (24V, 40 Amp).
    $494
  • HVACPhotograph shows an HVAC contactor with heavily pitted and burned contact points, yellow and brown wires connected to terminals, and a red wire nut; the contactor label partially reads 'PER POLE / LRA / RES / 40'.
  • HVACPhotograph shows the interior electrical compartment of an outdoor HVAC condenser unit, with a cylindrical run capacitor and a contactor relay visible, connected by multiple colored wires (yellow, orange, red, purple, gray, green); dirt and debris are present on the unit's base pan.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Plumbing
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby homes with documented history