- HVAC · Furnace safety switch replaced and inducer cleaned to restore heat · Nov 2025
- HVAC · Seasonal maintenance found dirty blower motor and failing inducer motor windings · Nov 2025
- HVAC · Outdoor AC unit found low on refrigerant; cleaning and top-off not performed, monitoring recommended · Jun 2026
- HVAC · Outdoor AC unit cleaned; mismatched R-22 outdoor unit paired with newer furnace and 410a coil noted · Jul 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 4 documented records for 4140 Michigan Avenue, St. Louis, MO 63118, dated from November 2025 through July 2026. The amount summary includes $902 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Seasonal Maintenance — Inducer motor windings going bad
- HVAC
Built from Housecall Pro data
- $89HVACSeasonal maintenance performed; blower motor found dirty and needing cleaning, and inducer motor windings starting to go bad with replacement recommended; system working but not efficiently.
- HVACPhotograph shows the interior of a gas furnace with the access panel removed, revealing the draft inducer blower motor, gas valve assembly, PVC piping, multi-colored wiring harnesses, pressure switch, and copper gas supply piping on the right side.
- HVACPhotograph shows an HVAC squirrel-cage blower wheel and motor assembly inside an air handler or furnace cabinet, with a multi-colored wiring harness visible at lower right and a tool being held near the blower housing.
- HVACPhotograph shows an HVAC blower wheel (squirrel cage fan) with heavy accumulation of dust, dirt, and debris coating the blades and surrounding scroll housing, indicating significant lack of maintenance.
- HVACPhotograph shows a forced-air gas furnace with manufacturer data plate visible; model G1D91BU075D12B-2A, serial number 8406C03861, Type FSP, natural gas, with exposed wiring visible at the base of the unit.
- HVACPhotograph shows a forced air furnace data plate with model G1D91BU075D12B-2A, serial 8406C03861, rated 75,000 BTU/H input and 68,250 BTU/H max output, 120V/1-phase/60Hz, 12 max amps, natural gas.
- HVACthe motor is visibly dusty and a lubrication needle tool is positioned at the motor's oil port (orange-ringed bearing port)
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Repair — Furnace safety replaced, inducer cleaned
- HVAC
Built from Housecall Pro data
- $375HVACFurnace was not working; replaced the safety and cleaned the inducer, and the system was working as intended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Clogged filter changed; older R22 system low
- HVAC
Built from Housecall Pro data
- $154HVACResponded to a no-AC call, verified the unit on the ground, found the system working, and changed a clogged filter; the older R22 system is low on refrigerant and dirty, and cleaning and topping off would exceed 500, so monitoring was recommended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — R-22 outdoor unit mismatched with 410a coil
- HVAC
Built from Housecall Pro data
- $284HVACService call for no AC; cleaned extremely dirty outdoor unit, which appears to be R-22 paired with a newer furnace and 410a coil, and recommended replacing the AC coil.