Hi, I'm 4159 Lindell Boulevard. I only speak from this property's source-backed records — 15 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
4159 Lindell Boulevard
Across 15 records on this property
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Fresh House Property Summary
Highlights selected from 15 documented records for this property.
- HVAC · Rooftop gas package unit replaced with crane and permits · Oct 2023$12k
- HVAC · Indoor fan inverter motor replaced on Carrier rooftop unit · Jun 2023
- HVAC · Two rooftop units serviced; condenser fan motor replaced · Oct 2023
- HVAC · Dual capacitor replaced on rooftop unit; service call 2025 · Jul 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 15 documented records for 4159 Lindell Boulevard, St. Louis, MO 63108, dated from June 2023 through October 2026. The amount summary includes $16,882.80 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Maintenance Tune-Up — Quarterly maintenance on 2 furnace systems
- HVAC
Built from Housecall Pro data
- $258HVACQuarterly maintenance tune-up performed on 2 furnace systems, including heat exchanger inspection, safety controls, carbon monoxide test, burner cleaning and airflow check; two 16x25x2 filters supplied.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Both units down; bad fan motor on back order
- HVAC
Built from Housecall Pro data
- $379HVACService call found both units down, with low voltage problems from overheating on the first unit and a bad fan motor on the second unit; the motor is on back order with Carrier.
- HVACPhotograph shows a rooftop HVAC unit with access panel open, revealing a blue-shrouded blower/fan motor assembly being tested with a Fluke 116 multimeter displaying a reading of 0.00.
- HVACa Puron refrigerant label is visible on the side panel
- HVACPhotograph shows the interior of an HVAC condenser unit with the access panel open, revealing a condenser coil heavily fouled with dust, dirt, and debris accumulation across its fin surface; multiple wires and refrigerant lines are bundled with a zip tie at the top of the coil, and the unit base pan shows staining and discoloration.
- HVACPhotograph shows an evaporator coil inside an air handler unit that is heavily coated in ice and frost, indicating a frozen coil condition; surrounding cabinet walls show quilted insulation and orange fiberglass insulation is visible at the left edge.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Fan Motor Replacement — Carrier RTU indoor fan motor replaced
- HVAC
Built from Housecall Pro data
- $1,912HVACRemoved and replaced the inverter motor for the indoor fan on a Carrier rooftop unit that was off due to a tripped safety on the motor; a test cycle found all other components functioning.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Return call for main unit down
- HVAC
Built from Housecall Pro data
- HVACReturn service call for main unit that was down.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Main unit bad compressor; fan wire repaired
- HVAC
Built from Housecall Pro data
- $317HVACService call found the main unit has a bad compressor (50-90 day back order); on the second unit a bad connection in the condenser fan motor was repaired by fixing the wire and it worked as expected, with no guarantee on length of repair.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Tune-Up — Two furnace tune-ups, condenser fan motor
- HVAC
Built from Housecall Pro data
- $383HVACFurnace tune-up performed on two Carrier units and condenser fan motor replaced.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Rooftop Unit Replacement — 4-ton gas rooftop unit replaced
- HVAC
Built from Housecall Pro data
- $11,521HVACReplaced 4 ton single-phase gas rooftop unit with a Sure Comfort by Rheem roof top package unit, including curb adapter, crane work and permits.
Documented warrantyfive-year / ten-year / twenty-year / 5 yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed by Contractor comes with a manufacturer five-year parts warranty”
- labor
· source
“Contractor offers a five-year labor warranty on all new equipment installed by contractor.”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
- parts and labor
· source
“All Commercial equipment will come with a 5 year parts and labor warranty with terms listed above.”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Thermostat Installation — Install Thermostat (Install new non
- HVAC
Built from Housecall Pro data
- $124HVACWork performed: Install Thermostat (Install new non programmable thermostat on new install).
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Tune-Up — Quarterly maintenance on 2 Carrier furnaces
- HVAC
Built from Housecall Pro data
- $258HVACQuarterly maintenance tune-up performed on two Carrier furnaces, including heat exchanger inspection, safety controls, carbon monoxide test, burner cleaning and filter check.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Invoice — Quarterly furnace maintenance, 2 units
- HVAC
Built from Housecall Pro data
- $258HVACPerformed quarterly furnace maintenance tune-up on 2 units, including heat exchanger inspection, carbon monoxide test, burner cleaning and filter check.
- HVACmodel 48TCEA06A2A3A0A0A0, serial 0513C88197, R-410A refrigerant, 208/230V single-phase 60Hz, 115,000 BTU/hr input, 90,000 BTU/hr output, 79.0% thermal efficiency
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Tune-Up — Maintenance tune-up on 2 Carrier furnaces
- HVAC
Built from Housecall Pro data
- $258HVACPerformed quarterly maintenance tune-up on two Carrier furnaces, including heat exchanger inspection, burner cleaning, carbon monoxide test, and airflow and safety control checks, with filters supplied.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Both systems working as intended
- HVAC
Built from Housecall Pro data
- $259HVACNormal hours service call and labor; thermostats found set to 66 with building at 69 on a 95 degree day, and both systems were working as intended and keeping up with the heat load.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — 45 + 7.5 Mfd dual capacitor supplied
- HVAC
Built from Housecall Pro data
- $440HVACTwo normal hours service calls performed and a 45 + 7.5 Mfd dual capacitor supplied.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Tune-Up — Quarterly tune-up on 2 Carrier furnaces
- HVAC
Built from Housecall Pro data
- $258HVACCommercial quarterly maintenance tune-up performed on two Carrier furnaces, including heat exchanger, burners, safety controls, carbon monoxide test and airflow checks, with filters 16x25x2 (qty 2) supplied.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Tune-Up — Quarterly maintenance on 2 Carrier systems
- HVAC
Built from Housecall Pro data
- $258HVACPerformed quarterly maintenance tune-up on 2 furnace systems, including heat exchanger inspection, carbon monoxide test, burner cleaning, and filter check, with filters 16x25x2 supplied.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this property.