- HVAC · Two furnaces and two AC units inspected, cleaned, and serviced · Jul 2026
- HVAC · Refrigerant added to AC system during service visit · Jul 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 4161 West Pine Boulevard, St. Louis, MO 63108, dated in July 2026. The amount summary includes $1,050 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Maintenance Service — Furnace and A/C tune-ups, refrigerant added
- HVAC
Built from Housecall Pro data
- $1,050HVACPerformed furnace inspection and cleaning and air conditioning inspection and maintenance on two units each, and added 410-A refrigerant (3 lb max).
- HVACPhotograph shows a heavily soiled HVAC air filter with dark brown/black filter media visible through a white louvered grille, indicating significant particulate accumulation and likely need for replacement.
- HVACPhotograph shows the exterior louver grille and aluminum condenser coil fins of an HVAC outdoor condensing unit, with fins appearing intact and some dust/debris accumulation visible on the fin surfaces.
- HVACPhotograph shows the exterior grille and condenser coil fins of an outdoor HVAC condenser unit; the aluminum fins appear dark and are visible through the white painted metal protective grille slats.
- HVACPhotograph shows multiple clamshell-style heat exchanger cells inside a furnace cabinet with visible rust and corrosion on the cell surfaces and metal dividers; a multi-wire harness (pink, white, orange, brown, blue wires) is bundled below the heat exchanger assembly.
- HVACPhotograph shows electrical wiring with cracked and split outer insulation lying on a wet, debris-covered surface outdoors, with inner conductors visibly exposed at a splice point near what appears to be HVAC equipment.
- HVACPhotograph shows a Yellow Jacket dual-gauge Test and Charging Manifold set (blue low-side and red high-side pressure gauges) with brass manifold body and service hose fittings, resting on a dirt/gravel surface.
- HVACPhotograph shows a digital thermometer (model DFP450W, NSF-certified, range -40/450°F) affixed to a galvanized metal HVAC duct surface displaying a reading of 137°F; the duct surface shows scattered moisture droplets or debris.
- HVAC1/4, FLA 17.9, LRA 112, working pressures Low 240 / High 450 PSIG, Serial No. 1405668962
- HVACPhotograph shows two Square D 60-amp, 10 kA, 120/240V double-pole circuit breakers mounted in an electrical panel with heavy dust and debris accumulation on the breakers and surrounding panel interior; multiple colored wires are visible entering from top and bottom.
- HVACPhotograph shows a metal panel interior with a white adhesive label identifying part number 0175M00008, rated 19.2Kw at 240V, Lot# 141767, dated 12/13; red, black, and blue conductors are connected to a terminal block with minor surface rust visible on hardware.
- HVACPhotograph shows a flat roof surface with a visible longitudinal crack running through the membrane, two insulated EPDM-jacketed pipes looping through the roof surface, and a dark mastic sealant patch at the pipe penetration point; additional smaller cracks are visible in the membrane.
- HVACPhotograph shows a yellow PRO+ DL389 TRMS digital multimeter displaying two readings (approximately 19.28 on the top line and 0.112 on the bottom line), with multiple colored wires visible in the background.
- HVACPhotograph shows a flat roof surface with a pipe/conduit penetration sealed using a large application of dark roofing mastic; bundled cables/conduit are zip-tied and pass through the penetration boot, and multiple linear cracks or seams are visible in the roofing membrane across the field of the roof.
- HVACa sticky note on the door references bedroom outlet breaker reset procedure
- HVAC · document contextPhotograph shows a digital thermometer (model DFP450W, NSF-certified) displaying a reading of 103.2°F, resting on a scratched flat surface.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.