Complete public upload archive

Property records for 4161 West Pine Boulevard, St. Louis, MO 63108

All 1 public upload record returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 1.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Maintenance Service — Furnace and A/C tune-ups, refrigerant added

  • HVAC

On July 9, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4161 West Pine Boulevard, St. Louis, MO 63108.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$1,050

    Performed furnace inspection and cleaning and air conditioning inspection and maintenance on two units each, and added 410-A refrigerant (3 lb max).

  • HVACWork status not resolved

    Photograph shows a heavily soiled HVAC air filter with dark brown/black filter media visible through a white louvered grille, indicating significant particulate accumulation and likely need for replacement.

  • HVACWork status not resolved

    Photograph shows the exterior louver grille and aluminum condenser coil fins of an HVAC outdoor condensing unit, with fins appearing intact and some dust/debris accumulation visible on the fin surfaces.

  • HVACWork status not resolved

    Photograph shows the exterior grille and condenser coil fins of an outdoor HVAC condenser unit; the aluminum fins appear dark and are visible through the white painted metal protective grille slats.

  • HVACWork status not resolved

    Photograph shows multiple clamshell-style heat exchanger cells inside a furnace cabinet with visible rust and corrosion on the cell surfaces and metal dividers; a multi-wire harness (pink, white, orange, brown, blue wires) is bundled below the heat exchanger assembly.

  • HVACWork status not resolved

    Photograph shows electrical wiring with cracked and split outer insulation lying on a wet, debris-covered surface outdoors, with inner conductors visibly exposed at a splice point near what appears to be HVAC equipment.

  • HVACWork status not resolved

    Photograph shows a Yellow Jacket dual-gauge Test and Charging Manifold set (blue low-side and red high-side pressure gauges) with brass manifold body and service hose fittings, resting on a dirt/gravel surface.

  • HVACWork status not resolved

    Photograph shows a digital thermometer (model DFP450W, NSF-certified, range -40/450°F) affixed to a galvanized metal HVAC duct surface displaying a reading of 137°F; the duct surface shows scattered moisture droplets or debris.

  • HVACWork status not resolved

    1/4, FLA 17.9, LRA 112, working pressures Low 240 / High 450 PSIG, Serial No. 1405668962

  • HVACWork status not resolved

    Photograph shows two Square D 60-amp, 10 kA, 120/240V double-pole circuit breakers mounted in an electrical panel with heavy dust and debris accumulation on the breakers and surrounding panel interior; multiple colored wires are visible entering from top and bottom.

  • HVACWork status not resolved

    Photograph shows a metal panel interior with a white adhesive label identifying part number 0175M00008, rated 19.2Kw at 240V, Lot# 141767, dated 12/13; red, black, and blue conductors are connected to a terminal block with minor surface rust visible on hardware.

  • HVACWork status not resolved

    Photograph shows a flat roof surface with a visible longitudinal crack running through the membrane, two insulated EPDM-jacketed pipes looping through the roof surface, and a dark mastic sealant patch at the pipe penetration point; additional smaller cracks are visible in the membrane.

  • HVACWork status not resolved

    Photograph shows a yellow PRO+ DL389 TRMS digital multimeter displaying two readings (approximately 19.28 on the top line and 0.112 on the bottom line), with multiple colored wires visible in the background.

  • HVACWork status not resolved

    Photograph shows a flat roof surface with a pipe/conduit penetration sealed using a large application of dark roofing mastic; bundled cables/conduit are zip-tied and pass through the penetration boot, and multiple linear cracks or seams are visible in the roofing membrane across the field of the roof.

  • HVACWork status not resolved

    a sticky note on the door references bedroom outlet breaker reset procedure

  • HVACWork status not resolved
  • UnclassifiedWork status not resolved

    Photograph shows a digital thermometer (model DFP450W, NSF-certified) displaying a reading of 103.2°F, resting on a scratched flat surface.

View 4161 West Pine Boulevard, St. Louis, MO 63108 on Fresh House