Hi, I'm 4171 CASTLEMAN. I only speak from this property's source-backed records — 3 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
4171 CASTLEMAN
Across 3 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Permitted value
Permitted value: the total declared on public permit filings for this address. It reflects amounts applied for or approved. It is not confirmed spending, and it does not mean the work was completed.
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 3 documented records
Fresh House Property Summary
Highlights selected from 3 documented records for this property.
- HVAC · AC drain line repaired with new 90° fitting and cleared · Aug 2026
- HVAC · Refrigerant charge and filter checked to prevent coil freezing · Aug 2026
RECORD SUMMARY
2 permit records on this page come from the City of St. Louis permit database. Community records come from 1 contributor.
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 3 documented records for 4171 CASTLEMAN, St. Louis, MO, dated from September 2020 through November 2020. The amount summary includes $219 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Installation — 90° fitting installed on kinked drain line
- HVAC
Built from Housecall Pro data
- $219HVACTechnician installed a new 90° fitting where the drain line was kinked, cleared the drain line, and checked the charge and filter to ensure the coil was not freezing.
- HVACPhotograph shows two copper refrigerant lines (suction and liquid) bending around the corner of a metal HVAC cabinet, with a galvanized duct fitting visible at right and debris on the cabinet top surface.
- HVACPhotograph shows water droplets and pooling on top of a metal appliance housing, with visible mineral staining and corrosion around a white plastic supply fitting and valve assembly, indicating an active or recent water leak at the connection point.
- HVACPhotograph shows a white PVC tee fitting with a small brass needle valve connected to a vertical PVC pipe, with copper/metal tubing routed toward an adjacent HVAC unit casing; older metal pipes and brick wall visible in background.
- HVACPhotograph shows a furnace data plate labeled AHI/ANI Certified for a Forced Air Furnace Cat. I, model ML180UH07QE36A-55, serial 1719J12353, rated 120V/60Hz/1-phase with 12.0 max amps and 1/2 HP blower motor; the surrounding metal surface shows rust staining and debris.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an HVAC system, displaying R454B refrigerant readings: low-side 127.5 psi with 18.8°F superheat (SH), high-side 313.0 psi with 5.8°F subcooling (SC).
- HVACPhotograph shows a Testo 557 digital manifold gauge displaying R454B refrigerant readings: suction side 126.9 psi with 21.3°F superheat (SH), high side 318.0 psi with 7.1°F subcooling (SC).
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
AP Permit AP-2020-186143
On November 18, 2020, City of St. Louis documented Plumbing at 4171 CASTLEMAN, St. Louis, MO.
Declared on the permit, not confirmed spending or proof of completed work.
Obtained from a public records source; may contain reporting delays or errors.
AP Permit AP-2020-183568
On September 29, 2020, City of St. Louis documented Plumbing at 4171 CASTLEMAN, St. Louis, MO.
Declared on the permit, not confirmed spending or proof of completed work.
Obtained from a public records source; may contain reporting delays or errors.
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.