← MAP

4300 Herbert Avenue

St. Louis, MO 6313438.7279°N, 90.3515°W
2Events
Contributed by:1 contributor
$4kDocumented amounts
SOURCE-BACKED RECORDS

Across 2 records on this home

Completed work

Invoices and paid receipts

$4k

Estimated · not confirmed

Quotes, estimates, and other amounts not confirmed as performed

None documented yet

Property History Report

Negotiate this home like you've seen its receipts. You have.

Free right now · built from this home's 2 documented records

Fresh House Property Summary

Highlights selected from 2 documented records for this property.

  • HVAC
    HVAC · New AC condenser and coil installed · Apr 2021
  • HVAC
    HVAC · AC unit inspected for noise; debris found on indoor coil from bad filter · Aug 2023
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 4300 Herbert Avenue. I only speak from this property's source-backed records — 2 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

2 documented events
Contributed by: 1 contributor
First documented event: Apr 2021
Latest documented event: Aug 2023
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 2 documented records for 4300 Herbert Avenue, St. Louis, MO 63134, dated from April 2021 through August 2023. The amount summary includes $4,017 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Installation — Rheem condenser and TXV installed

Document dated Apr 12, 2021Uploaded Nov 11, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 4300 Herbert Avenue, St. Louis, MO 63134.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $4,017
  • HVACInstalled Sure Comfort by Rheem condenser unit (M/N SA1324AJ1NA) with Sure Comfort by Rheem TXV (AC/Coil).
    $4,017
warranty5 year / 10 year / 20 year / one yearFrom invoiceView details
Documented warrantyfrom invoice · Apr 12, 2021HVAC · 6 terms

What this warranty covers

5 year
  • parts
    · source

    “All equipment installed comes with a 5 year parts warranty”

  • Labor
    · source

    “We do offer a 5 year Labor warranty for an additional $500”

10 year
  • compressor
    · source

    “10 year compressor warranty”

  • parts/compressor
    · source

    “Once equipment is registered this will become 10 year parts/compressor warranty”

20 year
  • heat exchanger
    · source

    “20 year heat exchanger warranty”

one year
  • labor
    · source

    “We offer a one year labor warranty at no additional cost.”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Unit Inspection — Indoor coil debris from bad filter

Document dated Aug 7, 2023Uploaded Nov 10, 20264 files
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 4300 Herbert Avenue, St. Louis, MO 63134.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

  • HVACInspected unit for a reported noise; found it working as intended with debris on the indoor coil from a bad filter, outdoor unit clean and charge looked okay, and advised customer to monitor the system.
  • HVACPhotograph shows a Rheem outdoor air conditioning unit data plate: Model SA1324BJ1NA, Serial W032145376, manufactured 01/2021, 208/230V, Phase 1, 60 Hz, R410A refrigerant, factory charge 66 oz/1871g.
  • HVACPhotograph shows a Rheem HVAC equipment data plate (model TCF2417STAMCA, serial W382007924) manufactured 09/2020, using R410A refrigerant at 550 PSI design pressure, UL listed, assembled in Mexico.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Plumbing
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby homes with documented history