- Electrical · Smoke detectors inoperable in multiple bedrooms, need replacement · 2026
- HVAC · Furnace and AC unit are 25-30 years old and likely need replacement soon · 2026
- Foundation · Basement wall crack letting moisture into the home · 2026
- Roof · Roof decking damaged and may need replacement at next re-roof · 2026
- Pest · Termite damage found on basement stairs, floor joists, and wall · 2026
Ask this homePowered by Fresh House property intelligence®
ASK ME ABOUT
RECORD SUMMARY
1 documented event
Contributed by: 1 contributor
First documented event: Jun 2026
Latest documented event: Jun 2026
First added to Fresh House: Jun 2026
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
DOCUMENTED HISTORY
This page contains 1 documented record for 9060 Patrick Drive, St. Louis, MO 63114, dated in June 2026.
Home Inspection
Home Inspection Document
Inspected Jun 26, 2026Uploaded Jun 29, 20262 files
Documented from uploaded report
Property Professional Uploaded
By
Greensmith Home Inspection llcdocumented Electrical, Foundation, HVAC, and 5 other topics at 9060 Patrick Drive, St. Louis, MO 63114.
Scope
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Windows
Contributor
worked on or inspected it- Home InspectionWhole-home inspection of 9060 Patrick Dr, Saint Louis, MO 63114 identified deficiencies across roofing, structure, HVAC, pest damage, electrical, plumbing, and interior systems, with no structural issues noted.
- PestWDI inspection found visible termite damage on basement stairs and footer of east-facing wall; termite treatment to the home is recommended.
- Electrical100-amp Square D service panel appears functional; inoperable smoke detectors in master bedroom and both second-floor rooms need replacement; GFCI outlet is absent in the laundry room and needs to be installed.
- FoundationCrack in the basement wall is allowing moisture intrusion and needs to be sealed; moisture intrusion was observed in the basement.
- HVACCentral split system with Bryant gas furnace and Gibson AC condenser estimated 25-30 years old is functioning but nearing end of expected lifespan and will likely require replacement soon; data plates on both units have faded.
- PestOlder termite damage is present to floor joists and stairwell in the basement; termite treatment is recommended unless seller proves prior treatment.
- PlumbingRheem 40-gallon natural gas water heater (manufactured 2018) is functioning properly; kitchen disposal (Badger) is newer but not working from the wall switch and needs repair.
- RoofArchitectural shingled roof (~10 years old) has damaged roof decking likely requiring replacement at next re-roof; one metal roof vent chewed down to 1" above roof line needs extension to minimum 6"; gutters on both sides of home are loose and need re-alignment.
- WindowsSeveral windows won't align to lock fully and require adjustment.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.
PROPERTY COVERAGE
Home Inspection
✓ documentedRoof
✓ documentedPlumbing
✓ documentedFoundation
✓ documentedElectrical
✓ documentedHVAC
✓ documentedPest
✓ documentedWindows
✓ documentedSewer
undocumentedMold
undocumentedRadon
undocumentedAppraisals
undocumented