Hi, I'm 7 Francis Court. I only speak from this property's source-backed records — 6 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
7 Francis Court
Across 6 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 6 documented records
Fresh House Property Summary
Highlights selected from 6 documented records for this property.
- HVAC · Furnace control board replaced and blower cleaned · Nov 2025
- HVAC · New non-programmable thermostat installed at the property · Jul 2026
- HVAC · Thermostat wiring diagnosed and new wire supplied · Mar 2026
- HVAC · Heating system maintenance performed under a residential plan · Oct 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 6 documented records for 7 Francis Court, St. Louis, MO 63114, dated from November 2025 through July 2026. The amount summary includes $1,557.50 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Furnace Repair — Furnace control board supplied, blower cleaned
- HVAC
Built from Housecall Pro data
- $899HVACDiagnostic trip, furnace control board supplied (universal replacement 120V HSI single stage board), and blower cleaning performed.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — HVAC diagnostic, thermostat wire supplied
- HVAC
Built from Housecall Pro data
- $310HVACPerformed a residential diagnostic service with 1.5 hours of labor and supplied 12 units of 18-6 thermostat wire.
- HVACPhotograph shows a Fluke 323 True RMS Clamp Meter clamped around wiring inside an HVAC air handler, displaying a reading of 6.7 A AC.
- HVACPhotograph shows a metal HVAC air handler unit in an open wall/utility chase with sheet metal ductwork and foil-mastic tape sealing
- HVACPhotograph shows a furnace or air handler unit with rigid and flexible flue/exhaust piping, sheet metal ductwork connections at the top (with foil tape), a service company sticker affixed to the cabinet face, and a yellow handheld instrument (possibly a combustion analyzer) resting against the unit.
- HVACPhotograph shows a gas furnace in a basement with sheet metal supply plenum, a round flue/exhaust pipe exhibiting dark soot and debris accumulation at the elbow joint, a combustion analyzer instrument resting on the furnace cabinet, and a service sticker affixed to the unit.
- HVACPhotograph shows a Testo digital manifold gauge set connected to an HVAC refrigerant system, displaying high-side pressure of 300.3 psig (HP dew 96.0°F), low-side pressure of 129.9 psig (LP evap 44.9°F), suction line temp 55.4°F, and subcooling/superheat value of 10.5°F.
- HVACPhotograph shows the interior of an HVAC unit with the access panel removed, revealing a green control board with an illuminated red LED indicator, multiple colored wiring harnesses bundled with cable ties, warning labels, and a white multi-pin connector; dust and debris are visible on interior surfaces.
- UnclassifiedPhotograph shows a dark-colored appliance with a handle and ribbed door panel positioned in a corner or tight space adjacent to a white wall or door frame, viewed from a tilted angle.
- UnclassifiedPhotograph shows a collapsed or damaged drop ceiling section in a finished lower-level room, with a bent metal grid rail hanging down and an exposed opening revealing deteriorated, discolored material above the ceiling plane.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge HVAC service call
- HVAC
Built from Housecall Pro data
- HVACPhotograph shows the interior of a gas furnace with multiple burners actively firing; flame color is blue on the left burners and transitions to reddish-orange on the right burners, suggesting uneven combustion across the burner array. A gas valve/manifold is visible above, and wiring is routed below the burner assembly.
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Thermostat Installation — Non-programmable thermostat installed
- HVAC
Built from Housecall Pro data
- $349HVACInstalled a non-programmable thermostat and performed a residential diagnostic service.
- HVACTenants report the HVAC system blows air when set to Cool/On but does not blow air when set to Cool/Auto; service appointment requested with JLM HVAC.
- HVACPhotograph shows Fieldpiece app air-side measurements: Return Dry Bulb 58.3°F / Wet Bulb 57.6°F / RH 95.8% / Dew Point 57.1°F / Enthalpy 24.8 Btu/lbm; Supply Dry Bulb 76.9°F / Wet Bulb 67.4°F / RH 61.3% / Dew Point 62.5°F / Enthalpy 31.9 Btu/lbm; Delta T -18.6°F; refrigerant-side probes not linked.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Warranty Trip — Warranty trip, no charge
- HVAC
Built from Housecall Pro data
- HVACWarranty trip service visit performed at the property.
- HVACTenants report the system blows air when set to Cool/On but does not blow when set to Cool/Auto; service appointment requested with JLM HVAC.
- HVACsystem is in Cool On mode with fan set to Auto On
- HVACthe LCD display is blank/off and mode selectors for Cool/Off/Heat and Fan On/Auto are visible
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Heating Maintenance — Heating maintenance under maintenance plan
- HVAC
Built from Housecall Pro data
- HVACHeating maintenance performed under the Residential Maintenance Plan.
- HVACPhotograph shows the interior of a gas furnace burner compartment, including a gas valve with a circular diaphragm cap, a multi-port burner rail, yellow and red control wiring, and associated ignition components; surfaces show dust and age-related soiling.
- HVACPhotograph shows the interior of a gas furnace with the access panel removed, revealing multiple burners with active blue flames, a draft inducer motor assembly, gas valve, heat exchanger ports, and wiring harnesses; warning labels are visible on the lower panel.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,