Hi, I'm 4338 Ventura Place Drive. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
4338 Ventura Place Drive
Across 1 record on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · AC compressor replaced with a new unit · Aug 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 4338 Ventura Place Drive, St. Louis, MO 63128. The amount summary includes $3,310 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Compressor Replacement — HVAC compressor replaced
- HVAC
Built from Housecall Pro data
- $3,310HVACReplaced compressor with a new unit in the HVAC system.
- HVACPhotograph shows a Fieldpiece app screen displaying live refrigerant measurements for an R-410A system: suction pressure 112.0 psig, suction temperature 49.7°F, actual superheat 12.7°F, liquid pressure 322.0 psig, liquid temperature 98.6°F, actual subcooling 2.1°F, and discharge pressure 322.0 psig.
- HVACFieldpiece app refrigerant-side measurements show R-410A system with suction pressure 130.5 psig, suction temperature 55.4°F, actual superheat 10.4°F, liquid pressure 319.2 psig, liquid temperature 97.7°F, actual subcooling 2.4°F, and discharge pressure 319.2 psig; air-side diagnostics show no connected tools.
- HVACPhotograph shows a Fluke 323 True RMS Clamp Meter displaying a reading of 0.4 A AC, with the rotary dial set to the amperes position, being used near outdoor wiring.
- HVACPhotograph shows a scroll compressor with model ZP21LXE-PFV-800 and serial 26G101A7M installed inside an outdoor condenser unit, with a technician partially visible in the background.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.