- HVAC · Gas furnace replaced with a new unit · Apr 2026
- HVAC · Fused disconnect installed and refrigerant leak search performed · Mar 2026
- HVAC · HVAC system found off with low refrigerant and frozen coil; replacement recommended · Apr 2024
- HVAC · Residential HVAC diagnostic service visit performed · Jun 2026
- HVAC · AC callback work order opened for system still blowing cold air · Apr 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 6 documented records for 4504 Anderson Avenue, St. Louis, MO 63115, dated from April 2026 through June 2026. The amount summary includes $5,350.50 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Low refrigerant, frozen coil; replacement advised
- HVAC
Built from Housecall Pro data
- $152HVACService call performed: system found off, refrigerant low, coil freezing over with frozen lineset at the adapter, system turned off; 2007 condenser and 2006 furnace noted as aging with replacement recommended.
- HVACPhotograph shows a copper pipe with a brass compression fitting passing through a ragged, torn drywall opening; electrical wires and a white cable are also visible through the wall cavity, and the surrounding drywall is damaged with exposed insulation/vapor barrier material.
- HVACPhotograph shows the interior of a gas furnace with the access panel open, revealing heavily dust-laden heat exchanger cells, burner assembly, gas valve, inducer motor, and associated wiring; significant debris accumulation is visible throughout the combustion chamber area.
- HVACPhotograph shows a wall-mounted tankless water heater with gas and water pipe connections, a yellow gas shutoff valve at the base, and electrical conduit/junction boxes above, installed in a tight utility space alongside a large storage tank bearing flammable vapor warning labels.
- HVACPhotograph shows a cluster of heavily corroded metal pipes with mineral deposits and white joint sealant at fittings, a yellow-handled ball valve, and a black flexible line, located in a tight mechanical space beside a louvered appliance.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — Fused disconnect and refrigerant leak search
- HVAC
Built from Housecall Pro data
- $660HVACProvided a fused disconnect and seal tight and performed a refrigerant leak search on the HVAC system.
- HVACPhotograph shows the interior of an HVAC air handler/furnace with the access panel removed, revealing a large blower motor assembly, multiple multi-colored wiring harnesses, and control components heavily coated in dust and debris; the sheet metal cabinet exhibits significant rust and corrosion, the top cabinet seal/insulation appears charred or severely deteriorated, and the evaporator coil or filter area shows heavy white crystalline buildup, indicating a severely neglected and potentially hazardous unit.
- HVACPhotograph shows a JB brand refrigerant manifold gauge set (blue low-side and red high-side gauges) connected to an outdoor HVAC condenser unit; gauges are scaled for R-410A, R-32, and R-454B refrigerants, 0; 500 psi range with -30 in.Hg vacuum, assembled in USA.
- HVACPhotograph shows an exterior HVAC condenser unit visible in the background adjacent to the electrical disconnect box, consistent with the disconnect serving the AC system.
- HVACPhotograph shows an evaporator coil unit with heavily deteriorated, torn, and crinkled foil tape sealing around refrigerant line penetrations and cabinet seams; drain connections and a flexible hose are visible at the base of the unit in a dirty, debris-filled space.
- HVACPhotograph shows a borescope camera screen displaying the interior of an HVAC heat exchanger with visible cracks and dark scoring/deposits along the metal surfaces; a blower motor assembly is visible in the background.
- HVACPhotograph shows a dark electrical cable with a visible red/orange wire splice connector located outdoors amid dense dead vegetation and leaf debris, near what appears to be an HVAC condenser unit; gray conduit or hose runs are also visible in the same area.
- HVACunit is R-410A refrigerant, 208-230V single-phase, with refrigerant service gauges connected to service ports unit is surrounded by leaf debris
- HVACPhotograph shows a Square D residential electrical panel (model HOMC24UC) with a 100-amp main breaker; installed breakers include 30A double-pole, 20A, and 15A single-pole breakers; many slots are empty; circuit directory labels only slots 1; 4 (Dryer, A/C, Dryer, A/C), with slots 5; 24 blank.
- HVACModel PG8MAA042090ACJA, Serial 2805A21377, 88,000 BTU/HR input, 71,000 BTU/HR output, manufactured July 2005
- HVACPhotograph shows a furnace/air handler with the access panel removed, exposing internal wiring, control board, blower motor, and heat exchanger components; floor area below the unit has debris and loose flexible hoses.
- HVACPhotograph shows interior of a residential electrical panel with a 100-amp main breaker, two double-pole 30-amp breakers, and at least two single-pole 15-amp breakers (Square D Type HOM, 10 kA, 120/240V); rust/corrosion staining is visible on the panel enclosure surface.
- HVACdebris and nesting material are visible in the mortar joint directly above the box
- HVACPhotograph shows a UEi PDT650 pocket thermometer placed on a floor-level supply air register displaying a temperature reading of 118°F.
- HVACPhotograph shows heavily dust- and debris-laden sheet metal ductwork and a ceiling-mounted supply/return grille that is severely soiled; a hole is visible in the ceiling drywall adjacent to the grille.
- HVACPhotograph shows an outdoor air conditioning condenser unit enclosed in a metal security cage, with a removed electrical contactor component (black relay block with copper contact terminals) resting on top of the cage grating alongside leaf and twig debris.
- HVACPhotograph shows a sewer scope camera device in use in what appears to be a crawl space or basement, with the display screen revealing visible cracks and fractures along the interior wall of the pipe being inspected.
- HVAChandwritten '16x20' is marked on the duct frame, and the surrounding drywall shows deterioration at the duct opening edges
- HVACPhotograph shows a 16x20 wall-mounted return air vent register that is bent, warped, and partially dislodged from its opening, leaving a visible gap at the top exposing the duct interior; the register, wire mesh screen, and surrounding galvanized duct box show heavy dust and grime accumulation.
- HVACPhotograph shows the LCD screen of a pipe inspection camera displaying the interior of a pipe with visible surface cracking, iridescent staining, and two circular lateral openings or joints.
- HVACPhotograph shows a heavily deteriorated outdoor HVAC condenser unit with extensive vine/root overgrowth covering the unit housing and surrounding brick wall, rust and corrosion on the metal cabinet, accumulated debris on the ground, and a refrigerant/conduit line running along the exterior brick wall being pointed to by an inspector.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Installation — 80% AFUE Merit ML180 gas furnace
- HVAC
Built from Housecall Pro data
- $4,320HVACFurnished an 80% AFUE Merit ML180UH070E36AK gas furnace with journeyman and apprentice labor, AC install materials and a 3/8" filter drier.
- HVACPhotograph shows an open metal-framed floor access pit set into a concrete subfloor, with multiple exposed pipes, fittings, and a yellow-handled shutoff valve visible; a blue level, screwdriver, and power tool are present indicating active plumbing work in progress; surrounding walls and floor show significant brown water staining.
- HVACPhotograph shows a metal HVAC cabinet panel with two adhesive identification labels: model/part label reading 'ML180DF070E36BK-01' and '25-1906C01L', with a note 'NAMEPLATE ADJACENT OR ON BLOWER ACCESS', and a second barcode label reading '726C09656'.
- HVACthe wood floor beneath the unit shows dark staining
- HVACPhotograph shows a rectangular sheet metal duct box or plenum positioned on a concrete subfloor surface, with bolted corner flanges, alongside a spirit level, screwdriver, and wiring, suggesting active duct installation in progress.
- HVACPhotograph shows a tall gray gas furnace installed in a utility area, with a metal flue pipe exiting through the ceiling, louvered intake vents at the base, warning and data plate labels on the front panel, and gas supply piping with a yellow shutoff valve visible to the right.
- HVACPhotograph shows an exposed evaporator coil unit sitting on a wooden platform on the floor of a utility closet, with refrigerant/copper lines visible beneath and no enclosure cabinet in place; the unit appears mid-installation or mid-service.
- HVAC · document contextPhotograph shows multiple woody shrub canes at ground level, with one central cane exhibiting a brownish, papery, peeling area on the bark mid-stem, surrounded by dried leaf litter and debris.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge HVAC service visit
- HVAC
Built from Housecall Pro data
- HVACService visit at 4504 Anderson Avenue on April 4, 2026 with no service lines itemized.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge service visit, no work itemized
- HVAC
Built from Housecall Pro data
- HVACInvoice for HVAC service visit on April 30, 2026 at 4504 Anderson Avenue with no service lines itemized.
- HVACCall back work order for AC still blowing cold air at 4504 Anderson Ave St. Louis, MO 63115; high priority, due 4/30/26.
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Diagnostic Service — Residential HVAC diagnostic service
- HVAC
Built from Housecall Pro data
- $219HVACPerformed residential diagnostic service with residential labor (non-member) at the service address.
- HVACPhotograph shows the exterior louvered panel of an outdoor HVAC condenser unit with wavy aluminum coil fins visible through the vents; debris accumulation (leaves and organic matter) is present at the base and lower vent openings, and surface rust/corrosion staining is visible on the right side of the housing.
- HVACPhotograph shows the exterior louvered grille of an outdoor HVAC condenser unit with condenser fins visible through the openings, debris (leaves and dirt) accumulated at the base, and white residue/staining on the upper right portion of the panel.
- HVACPhotograph shows the exterior louvered panel of an outdoor HVAC condenser unit with the lower row of louver openings visibly packed with accumulated leaf and organic debris; upper louvers appear dusty but less obstructed.
- HVACPhotograph shows an outdoor HVAC condenser unit surrounded by dense vegetation including vines and weeds, with a wire mesh guard/cage overlaying the unit; the louvered top panel and fin coil are visible through the guard.
- HVACPhotograph shows an outdoor HVAC condenser unit tilted on its side and heavily surrounded by overgrown vines and vegetation, with a wire mesh guard visible in the foreground.
- HVACthe unit has Heat/Off/Cool and Fan Auto/On slide switches
- HVACPhotograph shows the exterior louver panel and condenser coil fins of an outdoor HVAC unit with visible dirt accumulation on the fins, debris (leaves and organic matter) collected at the base, and white mineral staining/deposits on the right side of the grille.
- HVAC · document contextLouis, MO 63115
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.