HVACCompleted work$660
Provided a fused disconnect and seal tight and performed a refrigerant leak search on the HVAC system.
HVACWork status not resolved
Photograph shows the interior of an HVAC air handler/furnace with the access panel removed, revealing a large blower motor assembly, multiple multi-colored wiring harnesses, and control components heavily coated in dust and debris; the sheet metal cabinet exhibits significant rust and corrosion, the top cabinet seal/insulation appears charred or severely deteriorated, and the evaporator coil or filter area shows heavy white crystalline buildup, indicating a severely neglected and potentially hazardous unit.
HVACWork status not resolved
Photograph shows a JB brand refrigerant manifold gauge set (blue low-side and red high-side gauges) connected to an outdoor HVAC condenser unit; gauges are scaled for R-410A, R-32, and R-454B refrigerants, 0–500 psi range with -30 in.Hg vacuum, assembled in USA.
HVACWork status not resolved
Photograph shows an exterior HVAC condenser unit visible in the background adjacent to the electrical disconnect box, consistent with the disconnect serving the AC system.
HVACWork status not resolved
Photograph shows an evaporator coil unit with heavily deteriorated, torn, and crinkled foil tape sealing around refrigerant line penetrations and cabinet seams; drain connections and a flexible hose are visible at the base of the unit in a dirty, debris-filled space.
HVACWork status not resolved
Photograph shows a borescope camera screen displaying the interior of an HVAC heat exchanger with visible cracks and dark scoring/deposits along the metal surfaces; a blower motor assembly is visible in the background.
HVACWork status not resolved
Photograph shows a dark electrical cable with a visible red/orange wire splice connector located outdoors amid dense dead vegetation and leaf debris, near what appears to be an HVAC condenser unit; gray conduit or hose runs are also visible in the same area.
HVACWork status not resolved
unit is R-410A refrigerant, 208-230V single-phase, with refrigerant service gauges connected to service ports unit is surrounded by leaf debris
HVACWork status not resolved
Photograph shows a Square D residential electrical panel (model HOMC24UC) with a 100-amp main breaker; installed breakers include 30A double-pole, 20A, and 15A single-pole breakers; many slots are empty; circuit directory labels only slots 1–4 (Dryer, A/C, Dryer, A/C), with slots 5–24 blank.
HVACWork status not resolved
Model PG8MAA042090ACJA, Serial 2805A21377, 88,000 BTU/HR input, 71,000 BTU/HR output, manufactured July 2005
HVACWork status not resolved
Photograph shows a furnace/air handler with the access panel removed, exposing internal wiring, control board, blower motor, and heat exchanger components; floor area below the unit has debris and loose flexible hoses.
HVACWork status not resolved
Photograph shows interior of a residential electrical panel with a 100-amp main breaker, two double-pole 30-amp breakers, and at least two single-pole 15-amp breakers (Square D Type HOM, 10 kA, 120/240V); rust/corrosion staining is visible on the panel enclosure surface.
HVACWork status not resolved
debris and nesting material are visible in the mortar joint directly above the box
HVACWork status not resolved
Photograph shows a UEi PDT650 pocket thermometer placed on a floor-level supply air register displaying a temperature reading of 118°F.
HVACWork status not resolved
Photograph shows heavily dust- and debris-laden sheet metal ductwork and a ceiling-mounted supply/return grille that is severely soiled; a hole is visible in the ceiling drywall adjacent to the grille.
HVACWork status not resolved
Photograph shows an outdoor air conditioning condenser unit enclosed in a metal security cage, with a removed electrical contactor component (black relay block with copper contact terminals) resting on top of the cage grating alongside leaf and twig debris.
HVACWork status not resolved
Photograph shows a sewer scope camera device in use in what appears to be a crawl space or basement, with the display screen revealing visible cracks and fractures along the interior wall of the pipe being inspected.
HVACWork status not resolved
handwritten '16x20' is marked on the duct frame, and the surrounding drywall shows deterioration at the duct opening edges
HVACWork status not resolved
Photograph shows a 16x20 wall-mounted return air vent register that is bent, warped, and partially dislodged from its opening, leaving a visible gap at the top exposing the duct interior; the register, wire mesh screen, and surrounding galvanized duct box show heavy dust and grime accumulation.
HVACWork status not resolved
Photograph shows the LCD screen of a pipe inspection camera displaying the interior of a pipe with visible surface cracking, iridescent staining, and two circular lateral openings or joints.
HVACWork status not resolved
HVACWork status not resolved
Photograph shows a heavily deteriorated outdoor HVAC condenser unit with extensive vine/root overgrowth covering the unit housing and surrounding brick wall, rust and corrosion on the metal cabinet, accumulated debris on the ground, and a refrigerant/conduit line running along the exterior brick wall being pointed to by an inspector.