Record 1Public property record

HVAC Service Call — Low refrigerant, frozen coil; replacement advised

  • HVAC

On April 19, 2024, ASSURED HEATING AND COOLING documented HVAC at 4504 Anderson Avenue, St. Louis, MO 63115.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$152

    Service call performed: system found off, refrigerant low, coil freezing over with frozen lineset at the adapter, system turned off; 2007 condenser and 2006 furnace noted as aging with replacement recommended.

  • HVACWork status not resolved

    Photograph shows a copper pipe with a brass compression fitting passing through a ragged, torn drywall opening; electrical wires and a white cable are also visible through the wall cavity, and the surrounding drywall is damaged with exposed insulation/vapor barrier material.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with the access panel open, revealing heavily dust-laden heat exchanger cells, burner assembly, gas valve, inducer motor, and associated wiring; significant debris accumulation is visible throughout the combustion chamber area.

  • HVACWork status not resolved

    Photograph shows a wall-mounted tankless water heater with gas and water pipe connections, a yellow gas shutoff valve at the base, and electrical conduit/junction boxes above, installed in a tight utility space alongside a large storage tank bearing flammable vapor warning labels.

  • HVACWork status not resolved

    Photograph shows a cluster of heavily corroded metal pipes with mineral deposits and white joint sealant at fittings, a yellow-handled ball valve, and a black flexible line, located in a tight mechanical space beside a louvered appliance.

  • HVACWork status not resolved
Record 2Public property record

HVAC Service Invoice — Fused disconnect and refrigerant leak search

  • HVAC

On March 3, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4504 Anderson Avenue, St. Louis, MO 63115.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$660

    Provided a fused disconnect and seal tight and performed a refrigerant leak search on the HVAC system.

  • HVACWork status not resolved

    Photograph shows the interior of an HVAC air handler/furnace with the access panel removed, revealing a large blower motor assembly, multiple multi-colored wiring harnesses, and control components heavily coated in dust and debris; the sheet metal cabinet exhibits significant rust and corrosion, the top cabinet seal/insulation appears charred or severely deteriorated, and the evaporator coil or filter area shows heavy white crystalline buildup, indicating a severely neglected and potentially hazardous unit.

  • HVACWork status not resolved

    Photograph shows a JB brand refrigerant manifold gauge set (blue low-side and red high-side gauges) connected to an outdoor HVAC condenser unit; gauges are scaled for R-410A, R-32, and R-454B refrigerants, 0–500 psi range with -30 in.Hg vacuum, assembled in USA.

  • HVACWork status not resolved

    Photograph shows an exterior HVAC condenser unit visible in the background adjacent to the electrical disconnect box, consistent with the disconnect serving the AC system.

  • HVACWork status not resolved

    Photograph shows an evaporator coil unit with heavily deteriorated, torn, and crinkled foil tape sealing around refrigerant line penetrations and cabinet seams; drain connections and a flexible hose are visible at the base of the unit in a dirty, debris-filled space.

  • HVACWork status not resolved

    Photograph shows a borescope camera screen displaying the interior of an HVAC heat exchanger with visible cracks and dark scoring/deposits along the metal surfaces; a blower motor assembly is visible in the background.

  • HVACWork status not resolved

    Photograph shows a dark electrical cable with a visible red/orange wire splice connector located outdoors amid dense dead vegetation and leaf debris, near what appears to be an HVAC condenser unit; gray conduit or hose runs are also visible in the same area.

  • HVACWork status not resolved

    unit is R-410A refrigerant, 208-230V single-phase, with refrigerant service gauges connected to service ports unit is surrounded by leaf debris

  • HVACWork status not resolved

    Photograph shows a Square D residential electrical panel (model HOMC24UC) with a 100-amp main breaker; installed breakers include 30A double-pole, 20A, and 15A single-pole breakers; many slots are empty; circuit directory labels only slots 1–4 (Dryer, A/C, Dryer, A/C), with slots 5–24 blank.

  • HVACWork status not resolved

    Model PG8MAA042090ACJA, Serial 2805A21377, 88,000 BTU/HR input, 71,000 BTU/HR output, manufactured July 2005

  • HVACWork status not resolved

    Photograph shows a furnace/air handler with the access panel removed, exposing internal wiring, control board, blower motor, and heat exchanger components; floor area below the unit has debris and loose flexible hoses.

  • HVACWork status not resolved

    Photograph shows interior of a residential electrical panel with a 100-amp main breaker, two double-pole 30-amp breakers, and at least two single-pole 15-amp breakers (Square D Type HOM, 10 kA, 120/240V); rust/corrosion staining is visible on the panel enclosure surface.

  • HVACWork status not resolved

    debris and nesting material are visible in the mortar joint directly above the box

  • HVACWork status not resolved

    Photograph shows a UEi PDT650 pocket thermometer placed on a floor-level supply air register displaying a temperature reading of 118°F.

  • HVACWork status not resolved

    Photograph shows heavily dust- and debris-laden sheet metal ductwork and a ceiling-mounted supply/return grille that is severely soiled; a hole is visible in the ceiling drywall adjacent to the grille.

  • HVACWork status not resolved

    Photograph shows an outdoor air conditioning condenser unit enclosed in a metal security cage, with a removed electrical contactor component (black relay block with copper contact terminals) resting on top of the cage grating alongside leaf and twig debris.

  • HVACWork status not resolved

    Photograph shows a sewer scope camera device in use in what appears to be a crawl space or basement, with the display screen revealing visible cracks and fractures along the interior wall of the pipe being inspected.

  • HVACWork status not resolved

    handwritten '16x20' is marked on the duct frame, and the surrounding drywall shows deterioration at the duct opening edges

  • HVACWork status not resolved

    Photograph shows a 16x20 wall-mounted return air vent register that is bent, warped, and partially dislodged from its opening, leaving a visible gap at the top exposing the duct interior; the register, wire mesh screen, and surrounding galvanized duct box show heavy dust and grime accumulation.

  • HVACWork status not resolved

    Photograph shows the LCD screen of a pipe inspection camera displaying the interior of a pipe with visible surface cracking, iridescent staining, and two circular lateral openings or joints.

  • HVACWork status not resolved
  • HVACWork status not resolved

    Photograph shows a heavily deteriorated outdoor HVAC condenser unit with extensive vine/root overgrowth covering the unit housing and surrounding brick wall, rust and corrosion on the metal cabinet, accumulated debris on the ground, and a refrigerant/conduit line running along the exterior brick wall being pointed to by an inspector.

Record 3Public property record

HVAC Installation — 80% AFUE Merit ML180 gas furnace

  • HVAC

On April 1, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4504 Anderson Avenue, St. Louis, MO 63115.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$4,320

    Furnished an 80% AFUE Merit ML180UH070E36AK gas furnace with journeyman and apprentice labor, AC install materials and a 3/8" filter drier.

  • HVACWork status not resolved

    Photograph shows an open metal-framed floor access pit set into a concrete subfloor, with multiple exposed pipes, fittings, and a yellow-handled shutoff valve visible; a blue level, screwdriver, and power tool are present indicating active plumbing work in progress; surrounding walls and floor show significant brown water staining.

  • HVACWork status not resolved

    Photograph shows a metal HVAC cabinet panel with two adhesive identification labels: model/part label reading 'ML180DF070E36BK-01' and '25-1906C01L', with a note 'NAMEPLATE ADJACENT OR ON BLOWER ACCESS', and a second barcode label reading '726C09656'.

  • HVACWork status not resolved

    the wood floor beneath the unit shows dark staining

  • HVACWork status not resolved

    Photograph shows a rectangular sheet metal duct box or plenum positioned on a concrete subfloor surface, with bolted corner flanges, alongside a spirit level, screwdriver, and wiring, suggesting active duct installation in progress.

  • HVACWork status not resolved
  • HVACWork status not resolved

    Photograph shows a tall gray gas furnace installed in a utility area, with a metal flue pipe exiting through the ceiling, louvered intake vents at the base, warning and data plate labels on the front panel, and gas supply piping with a yellow shutoff valve visible to the right.

  • HVACWork status not resolved

    Photograph shows an exposed evaporator coil unit sitting on a wooden platform on the floor of a utility closet, with refrigerant/copper lines visible beneath and no enclosure cabinet in place; the unit appears mid-installation or mid-service.

  • UnclassifiedWork status not resolved

    Photograph shows multiple woody shrub canes at ground level, with one central cane exhibiting a brownish, papery, peeling area on the bark mid-stem, surrounded by dried leaf litter and debris.

Record 4Public property record

HVAC Service Invoice — No-charge HVAC service visit

  • HVAC

On April 4, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4504 Anderson Avenue, St. Louis, MO 63115.

Record date

Available findings

  • HVACCompleted work

    Service visit at 4504 Anderson Avenue on April 4, 2026 with no service lines itemized.

Record 5Public property record

HVAC Service Invoice — No-charge service visit, no work itemized

  • HVAC

On April 30, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4504 Anderson Avenue, St. Louis, MO 63115.

Record date

Available findings

  • HVACCompleted work

    Invoice for HVAC service visit on April 30, 2026 at 4504 Anderson Avenue with no service lines itemized.

  • HVACWork status not resolved

    Call back work order for AC still blowing cold air at 4504 Anderson Ave St. Louis, MO 63115; high priority, due 4/30/26.

Record 6Public property record

HVAC Diagnostic Service — Residential HVAC diagnostic service

  • HVAC

On June 10, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 4504 Anderson Avenue, St. Louis, MO 63115.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$219

    Performed residential diagnostic service with residential labor (non-member) at the service address.

  • HVACWork status not resolved

    Photograph shows the exterior louvered panel of an outdoor HVAC condenser unit with wavy aluminum coil fins visible through the vents; debris accumulation (leaves and organic matter) is present at the base and lower vent openings, and surface rust/corrosion staining is visible on the right side of the housing.

  • HVACWork status not resolved

    Photograph shows the exterior louvered grille of an outdoor HVAC condenser unit with condenser fins visible through the openings, debris (leaves and dirt) accumulated at the base, and white residue/staining on the upper right portion of the panel.

  • HVACWork status not resolved

    Photograph shows the exterior louvered panel of an outdoor HVAC condenser unit with the lower row of louver openings visibly packed with accumulated leaf and organic debris; upper louvers appear dusty but less obstructed.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit surrounded by dense vegetation including vines and weeds, with a wire mesh guard/cage overlaying the unit; the louvered top panel and fin coil are visible through the guard.

  • HVACWork status not resolved

    Photograph shows an outdoor HVAC condenser unit tilted on its side and heavily surrounded by overgrown vines and vegetation, with a wire mesh guard visible in the foreground.

  • HVACWork status not resolved

    the unit has Heat/Off/Cool and Fan Auto/On slide switches

  • UnclassifiedWork status not resolved

    Louis, MO 63115

  • HVACWork status not resolved

    Photograph shows the exterior louver panel and condenser coil fins of an outdoor HVAC unit with visible dirt accumulation on the fins, debris (leaves and organic matter) collected at the base, and white mineral staining/deposits on the right side of the grille.

View 4504 Anderson Avenue, St. Louis, MO 63115 on Fresh House