On August 19, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 6 other topics at 4974 Brookton Way, St. Louis, MO 63128.
- Record date
Available findings
- ElectricalWork status not resolved
One family room outlet has hot and neutral wires reversed and needs correction; GFCI outlets are missing at basement laundry and basement bar (within 6 ft of sink); smoke detector absent near basement gas appliances; master bathroom heat lamp switch is faulty and cannot be turned off.
- FoundationWork status not resolved
Previously repaired exterior foundation cracks are aged and dried and need to be resealed with fresh epoxy; large cracks present in concrete garage floor require repair; repaired basement wall crack appears functional with no moisture intrusion observed.
- Home InspectionWork status not resolved
Whole-home inspection of single-family property found home in generally good condition with no structural issues; deficiencies noted across site, roofing, electrical, HVAC, plumbing, sewer, foundation, windows, and interior systems.
- HVACWork status not resolved
HVAC information documented.
- PlumbingWork status not resolved
rear exterior faucet is non-functional and loose from the wall and needs repair
- RoofWork status not resolved
Architectural shingle roof estimated 1 year old and installed correctly; one plastic vent pipe flashing is improper and needs correction.
- SewerWork status not resolved
No damage observed to sewer lateral lines, but scaling has built up in the cast-iron section reducing pipe diameter and causing water to hold; hydroflushing recommended to remove scaling and restore flow.
- WindowsWork status not resolved
The window over the kitchen sink has a disconnected crank handle that needs to be reset, preventing the window from closing fully.
- SewerWork status not resolved
No structural damage observed to sewer lateral lines; however, scaling has built up and reduced the diameter of the line, and part of the cast-iron section is holding water due to scaling — hydroflushing recommended to remove scaling and restore flow.
- PestWork status not resolved
no action or treatment recommended