4974 Brookton Way

Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- Electrical · Reversed outlet wiring, missing GFCI outlets, and absent smoke detector found · 2026
- Foundation · Aged foundation cracks need resealing and garage floor cracks need repair · 2026
- Sewer · Scaling has narrowed sewer pipe and is holding water, flush recommended · 2026
- Roof · Roof about one year old but one vent pipe flashing needs correction · 2026
- Plumbing · Rear exterior faucet is non-functional and loose, needs repair · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 4974 Brookton Way, St. Louis, MO 63128, dated in August 2026.
Home Inspection Document
On August 19, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 6 other topics at 4974 Brookton Way, St. Louis, MO 63128.
- Electrical,
- Foundation,
- HVAC,
- Home Inspection,
- Pest,
- Plumbing,
- Roof,
- Sewer,
- Windows
- Home InspectionWhole-home inspection of single-family property found home in generally good condition with no structural issues; deficiencies noted across site, roofing, electrical, HVAC, plumbing, sewer, foundation, windows, and interior systems.
- ElectricalOne family room outlet has hot and neutral wires reversed and needs correction; GFCI outlets are missing at basement laundry and basement bar (within 6 ft of sink); smoke detector absent near basement gas appliances; master bathroom heat lamp switch is faulty and cannot be turned off.
- FoundationPreviously repaired exterior foundation cracks are aged and dried and need to be resealed with fresh epoxy; large cracks present in concrete garage floor require repair; repaired basement wall crack appears functional with no moisture intrusion observed.
- HVACHVAC information documented.
- Plumbingrear exterior faucet is non-functional and loose from the wall and needs repair
- RoofArchitectural shingle roof estimated 1 year old and installed correctly; one plastic vent pipe flashing is improper and needs correction.
- SewerNo damage observed to sewer lateral lines, but scaling has built up in the cast-iron section reducing pipe diameter and causing water to hold; hydroflushing recommended to remove scaling and restore flow.
- WindowsThe window over the kitchen sink has a disconnected crank handle that needs to be reset, preventing the window from closing fully.
- SewerNo structural damage observed to sewer lateral lines; however, scaling has built up and reduced the diameter of the line, and part of the cast-iron section is holding water due to scaling — hydroflushing recommended to remove scaling and restore flow.
- Pestno action or treatment recommended
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.