HVAC Seasonal Maintenance — Flex gas line with union not to code
- HVAC
On November 25, 2025, ASSURED HEATING AND COOLING documented HVAC at 5130 KENSINGTON, St. Louis, MO.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$89
Seasonal maintenance on vacant unit furnace: flame sensor was dirty and cleaned, system ran as it should, filter in good condition; flex gas line into furnace cabinet noted as not to code due to the union built into the flex line.
- HVACWork status not resolved
Photograph shows the interior of a gas furnace with access panels removed, revealing the inducer/draft blower motor at top, a gas valve with yellow corrugated gas supply line, multiple wiring harnesses, a circuit control board in the lower compartment, and a 3M Filtrete 16x25x1 air filter on the left side; exterior cabinet shows dust accumulation.
- UnclassifiedWork status not resolved
Photograph shows an extremely dark scene with a narrow band of dim blue-tinted light revealing indistinct rounded or arch-like silhouettes; the property system or component cannot be reliably identified.