Hi, I'm 5130 KENSINGTON. I only speak from this property's source-backed records — 8 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
5130 KENSINGTON
Across 8 records on this building
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Permitted value
Permitted value: the total declared on public permit filings for this address. It reflects amounts applied for or approved. It is not confirmed spending, and it does not mean the work was completed.
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 8 documented records
Fresh House Property Summary
Highlights selected from 8 documented records for this property.
- HVAC · Furnace hot surface igniter replaced; heat restored · Dec 2025
- HVAC · Thermostat replaced; both heat and AC restored · Oct 2025
- HVAC · AC compressor found shorted to ground; new coil needed · May 2026
- HVAC · AC condensing unit replacement estimated but not confirmed done · Jun 2026$7.9k
RECORD SUMMARY
1 permit record on this page come from the City of St. Louis permit database. Community records come from 1 contributor.
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 8 documented records for 5130 KENSINGTON, St. Louis, MO, dated from November 2021 through June 2026. The amount summary includes $1,290.20 in completed work across HVAC, $7,910 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Seasonal Maintenance — Flex gas line with union not to code
- HVAC
Built from Housecall Pro data
- $89HVACSeasonal maintenance on vacant unit furnace: flame sensor was dirty and cleaned, system ran as it should, filter in good condition; flex gas line into furnace cabinet noted as not to code due to the union built into the flex line.
- HVACPhotograph shows the interior of a gas furnace with access panels removed, revealing the inducer/draft blower motor at top, a gas valve with yellow corrugated gas supply line, multiple wiring harnesses, a circuit control board in the lower compartment, and a 3M Filtrete 16x25x1 air filter on the left side; exterior cabinet shows dust accumulation.
- UnclassifiedPhotograph shows an extremely dark scene with a narrow band of dim blue-tinted light revealing indistinct rounded or arch-like silhouettes; the property system or component cannot be reliably identified.
HVAC
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Seasonal Maintenance Visit — No access; system not serviced
- HVAC
Built from Housecall Pro data
- $89HVACSeasonal maintenance visit was billed, but the technician could not get into the unit because the lockbox codes did not work, so the system was not serviced.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Compressor shorted to ground; needs new coil
- HVAC
Built from Housecall Pro data
- $154HVACService call for no AC: verified system set to cool with blower on and clean filter, reset tripped breaker at outdoor unit, found compressor shorted to ground and a new 17 inch 2.5 ton AC coil is needed.
- HVACPhotograph shows four air conditioning condenser units mounted on an elevated, visibly rusted metal platform attached to the rear exterior of a multi-unit brick building.
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Estimate — 2.5-ton condenser install, relocated to ground
- HVAC
Option: Option #1 $7,910 (declined)
Built from Housecall Pro data
- $7,910HVACEstimate for installing a 2.5 ton 13.4 SEER2 R454B condensing unit with TXV cased coil, relocating it to the ground with rerouted line set and electrical, plus a theft deterrent cage.
Documented warrantyfive-year / ten-year / twenty-yearFrom estimateView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an estimate. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Thermostat Replacement — Faulty thermostat replaced
- HVAC
Built from Housecall Pro data
- $405HVACNo heat or AC call: system failed due to faulty thermostat; replaced the thermostat and both AC and heat work as intended; a new 16x25x1 filter is still needed.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Seasonal Maintenance — Unit 2 serviced; unit 1 not accessed
- HVAC
Built from Housecall Pro data
- $89HVACSeasonal maintenance performed on the second floor unit: cleaned flame sensor and installed a 20x25x1 filter; gas flex line was connected in the unit and redoing the gas is recommended; first unit was not serviced because no key was available.
- HVACPhotograph shows a gas furnace with the front access panel removed, exposing the inducer/draft motor assembly, gas valve, wiring harness, and yellow flexible gas connector; an EnergyGuide label on the unit face indicates 80.0% Annual Fuel Utilization Efficiency.
- HVACPhotograph shows the interior of an HVAC unit with severe rust and corrosion on the metal panel/burner box surface, multiple wiring harnesses bundled with tape, and wires passing through the heavily oxidized and flaking metal area.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC No Heat Repair — Broken igniter replaced, heat restored
- HVAC
Built from Housecall Pro data
- $465HVACNo heat service call: found a broken flame igniter, replaced the hot surface igniter, and the system worked as it should.
- HVACPhotograph shows the interior of an HVAC unit with the access panel removed, revealing a control board (marked '251') with a red fault indicator LED actively illuminated, multiple wiring harnesses connected, and heavy dust/debris accumulation on interior surfaces and the unit base.
- HVACPhotograph shows the interior of a gas furnace with the access panel removed, revealing active blue burner flames, a yellow corrugated flexible gas supply line, multiple control wires, and significant accumulation of rust, dirt, and debris on the lower pan/tray of the unit.
- HVACPhotograph shows the interior of a gas furnace with access panel removed, revealing the inducer/draft blower motor assembly, gas valve and manifold, burner assembly with wiring harnesses, and visible rust and debris accumulation on the burner deck floor; a technician's hand is holding a wiring harness.
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
AP Permit AP-2021-204579
On November 3, 2021, City of St. Louis documented Plumbing at 5130 KENSINGTON, St. Louis, MO.
Declared on the permit, not confirmed spending or proof of completed work.
Obtained from a public records source; may contain reporting delays or errors.
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this building.