Hi, I'm 5233 Greer Avenue. I only speak from this property's source-backed records — 2 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
5233 Greer Avenue
Across 2 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 2 documented records
Fresh House Property Summary
Highlights selected from 2 documented records for this property.
- HVAC · AC dual capacitor replaced and refrigerant recharged · Sep 2026
- HVAC · AC was not cooling; habitability-priority work order issued · Sep 2026
- HVAC · Pre-repair diagnostics showed severely abnormal refrigerant pressures · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 5233 Greer Avenue, St. Louis, MO 63115, dated in September 2026. The amount summary includes $700 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Repair — Dual capacitor replaced, refrigerant added
- HVAC
Built from Housecall Pro data
- $700HVACTrip fee, refrigerant charge (3 lbs max) added, and dual capacitor replaced.
- HVACRefrigerant diagnostic app shows R-410A system with suction pressure 144.6 psig, liquid pressure 409.2 psig, actual superheat 24.9°F, and actual subcooling 2.1°F; air side diagnostics show no tools connected.
- HVACRefrigerant side diagnostic shows R-410A system with suction pressure 29.1 psig, liquid pressure 166.0 psig, actual superheat 101.3°F (severely elevated), and actual subcooling -31.9°F (abnormal), indicating a likely refrigerant charge or system issue.
- HVACPhotograph shows Fieldpiece app refrigerant-side measurements for R-410A system: suction pressure 28.9 psig, suction temperature 84.2°F, vapor saturation -17.4°F, actual superheat 101.6°F; liquid pressure 165.9 psig, liquid temperature 90.2°F, liquid saturation 58.3°F, actual subcooling -31.9°F, discharge pressure 165.9 psig.
- HVACCentral AC is set to cool but producing no air in apartment with forecast temperatures up to 103°F; work order created with habitability priority to inspect and repair ASAP.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge HVAC service visit
- HVAC
Built from Housecall Pro data
- HVACPhotograph shows the interior of an outdoor HVAC condenser unit with dark metal louver grille slats in the foreground, copper refrigerant lines, multi-colored electrical wiring, and what appears to be a blue capacitor or electrical component visible through the grille.
- HVACPhotograph shows the top of an outdoor HVAC condenser unit, with the fan blade guard grille, fan motor housing, refrigerant lines, and wiring visible through the louvered slats.
- HVACPhotograph shows a white PVC condensate drain line passing through the base panel of an outdoor HVAC unit, with a small fitting at the base; metal structural frame and louvered cabinet visible above; ground covered with dry leaf debris.